| Copper and Aluminum Price Calculation |
Web Site |
 |
| Reference to DIN VDE Standards |
Web Site |
 |
| Harmonized Identification |
Web Site |
 |
| Designation Code for Harmonized Cables |
Web Site |
 |
| Code Designation for Harmonized Cables and Flexible Cords |
Web Site |
 |
| Comparison of Harmonized Cables with IEC, DIN VDE and HD |
Web Site |
 |
| Designation Code for Power Cables |
Web Site |
 |
| Designation Code for Telephone Cables, Jumper Wires & Stranded Hook-up Wires |
Web Site |
 |
| Code Designation Explanations for Cables and Insulated Wires |
Web Site |
 |
| Conductor Diameters according to VDE 0295 (DIN EN 60228) |
Web Site |
 |
| Conductor Resistance |
Web Site |
 |
| Strand Make-up according to DIN VDE 0295, IEC 60228 & HD 383 |
Web Site |
 |
| Nominal Voltage & Operating Voltage |
Web Site |
 |
| Current Carrying Capacity and Indications for Calculation of Power Cables & Wires |
Web Site |
 |
| Installation Methods & Operating Conditions |
Web Site |
 |
| Laying Conditions for Power Cables |
Web Site |
 |
to top  |
| Current Ratings for Installation
(A1, A2, B1 & B2 Cables for fixed installation within buildings, operating temperature at conductor 70°C, ambient temperature 30°C) |
Web Site |
 |
| Current Ratings for Installation
(C, E, F & G Cables for fixed installation within buildings, operating temperature at conductor 70°C, ambient temperature 30°C) |
Web Site |
 |
| Current Ratings for Installation
(A1, A2, B1 & B2 Cables for fixed installation within buildings, operating temperature at conductor 90°C, ambient temperature 30°C) |
Web Site |
 |
| Current Ratings for Installation
(C, E, F & G Cables for fixed installation within buildings, operating temperature at conductor 90°C, ambient temperature 30°C) |
Web Site |
 |
| Current Ratings for Cables & Insulated Wires up to 1000V & heat-resistant Cables |
Web Site |
 |
| Current Ratings for Cables ≤ 0.6/1 kV |
Web Site |
 |
| Current Ratings - General - for Flexible Cables |
Web Site |
 |
| Current Ratings for HELUTHERM® 145 |
Web Site |
 |
| Current Ratings for Silicone Cables & Wires |
Web Site |
 |
| Current Ratings for NYY, NAYY, NYCY, NYCWY, NAYCWY 0.6/1 kV |
Web Site |
 |
| Current Carrying Capacity for NYKY 0.6/1 kV |
Web Site |
 |
| Current Ratings - Conversion Factors for grouping on walls, on the floor, in insulation tubes / conduit and under the ceiling |
Web Site |
 |
| Current Ratings - Conversion Factors for deviating ambient temperatures |
Web Site |
 |
| Current Ratings - Conversion Factors for grouping of single conductors or cables on trays |
Web Site |
 |
| Current Ratings - Conversion Factors for grouping of multi conductors or cables on trays |
Web Site |
 |
| Power Ratings for XLPE-insulated Medium Voltage Power Cables |
Web Site |
 |
| Electrical Characteristics of XLPE-insulated Medium Voltage Power Cables 6 - 30 kV |
Web Site |
 |
| Rating Conversion Factors for Installation of Medium Voltage Power Cables 6 - 30 kV, for Single Conductor Cables in 3-phase systems |
Web Site |
 |
| Rating Conversion Factors for Installation of Medium Voltage Power Cables 6 - 30 kV, for Multi Conductor and Single Conductor direct current cable |
Web Site |
 |
| Conversion Factor for Medium Voltage Power Cables 6 - 30 kV |
Web Site |
 |
to top  |
| Color Code according to DIN VDE 0293 |
Web Site |
 |
| Color Code according to DIN VDE 0245 part 1 |
Web Site |
 |
| Color Code according to DIN 47100 |
Web Site |
 |
| Pair - Color Code according to DIN 47100 |
Web Site |
 |
| Color Code according to International Standards |
Web Site |
 |
| Color Code for Single Wire Vehicle Cables |
Web Site |
 |
| Color Code European-JB |
Web Site |
 |
| Color Code European-OB |
Web Site |
 |
| Color Code according to DIN VDE 0813 |
Web Site |
 |
| Color Code according to DIN VDE 0815 |
Web Site |
 |
| Color Code according to DIN VDE 0816 and extended |
Web Site |
 |
| Color Abbreviations according to VDE and IEC |
Web Site |
 |
| Identification of Insulated Wires by Colors according to DIN 40705 and CEI/IEC 60446 |
Web Site |
 |
| Permissible Minimum Bending Radius according to DIN VDE Specifications |
Web Site |
 |
| Chemical Resistance against Inorganic Chemicals |
N/A |
 |
| Chemical Resistance against Organic Chemicals |
N/A |
 |
| Chemical Resistance of PUR (Polyurethane) |
Web Site |
 |
| Chemical Resistance of Fluorinated Polymeric Materials |
Web Site |
 |
| Fluorinated Polymeric Materials: PTFE, FEP, PFA, ETFE |
Web Site |
 |
| Chemical Resistance of Silicone / Resistance of Substances against Solvents, oils and fats |
Web Site |
 |
to top  |
Heat-Resistance Classes as per VDE 0530 part 1
|
Web Site |
 |
| Caloric Load Values (Heat of Combustion) of Halogen-free Security Cables and Insulated Wires |
N/A |
 |
| Installation Instructions for UL and CSA Cables |
Web Site |
 |
| AWG Wires & AWG Stranded Conductors (Conductor Make-up, Cross Section & Weight) & AWG Wires (Solid Conductors) |
N/A |
 |
| US and British Units - Conversion of Measuring units |
Web Site |
 |
| Current Ratings for UL-CSA Cables |
Web Site |
 |
| List of UL-Styles (Single Conductor Cables) |
N/A |
 |
| List of UL-Styles (Multi Conductor Cables) |
N/A |
 |
| Index British Standard |
Web Site |
 |
| International Abbreviations |
Web Site |
 |
| Characteristics of Insulating and Jacket Materials |
N/A |
 |
| Definitions: Classes of Stress in Flexible Cables and Insulated Wires |
Web Site |
 |
| Safety Requirements when using Cables & Wires |
Web Site |
 |
| Glossary of Terms: Cables & Wires |
Web Site |
 |
| International Certification Marks & Testing Institute |
Web Site |
 |
| Formulas of Electrotechnic & Electronic |
Web Site |
 |
| Formulas of Power Engineering |
Web Site |
 |
| Capacity of KTG-Pool Drums |
Web Site |
 |
| Cable Length (m) to KTG-Drums - Capacity of Pool Drums |
Web Site |
 |
| Explanatory Notes on CE-Marking, Low Voltage Directive (NSR), EMC Legislation |
Web Site |
 |
| European Directives WEEE, RoHS & ElektroG |
Web Site |
 |
to top  |