Page 4 - Data, Network and Bus Technology
P. 4
i!I), HI·TECH (800) 877-8842 I (303) 880-5159 www_hltechcontrols_com
~ CONTROLS, INC. Click or Call for a Quotel
Industrial Ethernet HE~"IUIT-250S ~
S-FTP drag chain. NFPA 79 Edition 2007
HELUKASEL &-FTPSd'll4op(Jl<e"'"
Type Drag chain applications
Cable Structure 4x2xO_1S qmm (stranded)
Inner conductor diameter: Bare copper (AWG 26/19)
Core insulation: PP
Core colours: whlbl, wh/or, whlgn. whlbr
Stranding elements: Double-core
Screen 1: Star element
Inner sheath: FRNC
Screen 2: Polyester foil. AI-coated
Overall screening: Cu braid tinned
Outer sheath material: PUR
Cable outer diameter: Approx. 7.8 +-0.3 mm
Outer sheath colour: Green, similar to RAl 6018
Electrical Data
Impedance: 100 +-15 Ohm at 1 to 100 MHz
100 +-20 Ohm at 101 to 250 MHz
Operating capacity: 52 .0 nF/km nom.
Typical Values
Frequency (MHz) 10 16 62,5 100 250
Attenuation (db! 10m) 0,9 1,2 2,4 2,9 4 ,9
Next (db) 59,3 56,2 47,4 44,3 38,3
ACR (db) 58,4 55,0 45,0 41,4 33,4
Technical Data
Weight: approx. 63 .0 kg/km
M inimum bending radius during installation: 59.0 mm
Operating temperature range min.: -30"C
Operating temperature range max. : + 70"C
Copper weight: 34.0 kglkm
Standards
Applicable standards: EN 50173, ISO/IEC 11801 , EI.AJTIA 568-A, Category 6, flame-retardant to
IEC 60332-1-2 and VWl or FTl, oil-resistance in ace. w ith CSA-C22.2
UL style: CMX
Application
This copper data cable, designed specifically for extreme industrial applications, is the ideal solution for Ethernet applications;
superior transmission properties; suitable for use even under the most demanding conditions; designed for use in drag chains;
fire-proof and oil-resistant according to UlICSA, the cable can also be used in the USA and Canada.
Part No: 803387 , S-FTP4x2xAW G 26119 PUR drag chain
II: .... ___