Your One-Stop Solution For Cable & Wire Accessories!

RoHS Compliant Cables & Wires
Heat-Resistant Silicone Cables


Contact Us About Us  
 
LinkedIn Facebook Twitter Hi Tech Controls Blog google +
Cables & WiresEnclosures (Plastic & Metal)Pneumatic ComponentsLiquid Tight Strain Relief FittingsCircular ConnectorsConduit System (Tubing, Fittings, etc.)Accessories & Adapters, Reducers, Enlargers
 
easyquote
*E-mail
*Name
*Company
*Phone
*State
*Zip Code
*Country
Please answer the security question:
3+2=
(*) Required Fields
Catalogs / Samples, Full Quote & Contact Information
303-699-1135
1-800-456-9012
dropdownbox
PDF Printable PDF

European Heat-Resistant Cable: FZ-LSi/FZ-LS/Neon Light Cables

Silicone, Ignition Cable, Halogen-Free

Sealcon, Inc, European & Domestic cable

FZ-LSi/FZ-LS/Neon Light Cables, RoHS Compliant, RoHS Approved, Sealcon, European  , Heat Resistant / Compensating Cables

SiF/GL
SiD/GL
 
European Part-No. Description, Conductor Color & Cross-sec. mm2 Cond. make-up
n x wire Ø
Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
23110 FZ-LSi Ignition Cable 16 kV, blue, 0.5 7 x 0.3 5.0 4.8 36.0 20
23106 FZ-LSi Ignition Cable 16 kV, blue, 1.0 19 x 0.25 7.5 9.5 65.0 17
23107 FZ-LSi Ignition Cable 16 kV, blue, 1.5 28 x 0.26 8.5 14.4 88.0 16
 
European Part-No. Description, Conductor Color & Cross-sec. mm2 Cond. make-up
n x wire Ø
Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
23109 FZ-LS High Voltage Ignition Cable 15/20 kV, red-brown, 1.0 19 x 0.25 5.0 9.6 34.0 17
23108 FZ-LS High Voltage Ignition Cable 15/20 kV, red-brown, 1.0 19 x 0.25 7.0 9.6 60.0 17
 
European Part-No. Description, Conductor Color & Cross-sec. mm2 Cond. make-up
n x wire Ø
Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
23147 Neon Light Cable 3.5kV, 4.5kV & 7.5kV, yellow, 1.5 30 x 0.25 4.4 14.4 32.0 16
23148 Neon Light Cable 3.5kV, 4.5kV & 7.5kV, yellow, 1.5 30 x 0.25 6.6 14.4 59.0 16
23149 Neon Light Cable 3.5kV, 4.5kV & 7.5kV, yellow, 1.5 30 x 0.25 7.6 14.4 75.0 16
Technical Data European
FZ-LSi, blue
  • Test Voltage 20 kV
  • Breakdown Voltage min. 30 kV
  • Ignition Voltage (kV eff.)
    0.5 mm² = 6 kV
    1.0 mm² = 8 kV
    1.5 mm² = 10 kV
FZ-LS, red
  • Test voltage
    for 5 mm Ø = 15 kV
    for 7 mm Ø = 20 kV
  • Breakdown voltage
    for 5 mm Ø: min. 25 kV
    for 7 mm Ø: min. 35 kV
Neon-light-Cable, yellow
  • Nominal voltage
    3.5 kV, 4.0 kV / 7.5 kV
  • Test voltage 10 kV
  • Specific volume resistive
    min. 1012 Ohm x cm
  • Minimum bending radius
    approx. 7.5x cable Ø
  • Radiation resistance
    up to 20x106 cJ/kg (up to 20 Mrad)
Approvals
RoHSVDE
Cable Construction  

FZ-LSi, blue

  • Tinned copper stranded conductor, strand make-up see table below
  • Silicone conductor insulation 2GI1 to DIN VDE 0207 part 20
  • Glass-fiber braiding
  • Outer-jacket silicone 2GM1 to DIN VDE 0207 part 21
  • Jacket color: Blue
FZ-LS, red
  • Adapted to ISO 3808 part 1
  • Tinned copper conductor, 19x0.25 mm Ø
  • Silicone conductor insulation 2GI1 to DIN VDE 0207 part 20
  • Jacket color: Red Brown
Neon-light-cable, yellow
  • in adapted to DIN VDE 0250 part 1 and part 5
  • Tinned copper stranded conductor 30x0.25 mm Ø
  • Silicon conductor insulation 2GI1 to DIN VDE 0207 part 20
  • Jacket color: Yellow
Application  
FZ-LSi, blue
This ignition cable is suitable for use at high and extremely alternating temperatures up to +180°C/+356°F and also for motor vehicle sector. As protection against mechanical damages a glass fiber braiding and a silicone jacket covers the conductor insulation.
FZ-LS, red
This ignition cable is suitable for use at high and extremely alternating temperatures up to +180°C/+356°F. Applications include the lamp and lighting industry and cooling and air conditioning technology.
Neon-light-cable, yellow
This cable is primarily suitable for use at high and extremely alternating ambient temperatures such as in the lamp and lighting industry. Protected installation is required.
Properties  
Neon-light-cable, yellow
  • Halogen-free according to VDE 0482 part 267 / DIN EN 50267-2-2/ IEC 60754-2 (equivalent DIN VDE 0472 part 813)
  • No flame propagation according to DIN VDE 0482 part 265-2-1 / EN 50265-2-1 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
  • No formation of corrosive gases
  • Low smoke density
  • Very good weather resistance

Note  
  • AWG sizes are approximate equivalent values. The actual cross-section is in mm².
Cable Accessories  
  • Coming Soon!
Cable Technical Data Construction and ApplicationProperties and Note Accessories
quote
Items For Quote

   
quote
box
Sealcon is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135 FAX: 303-680-5344
Valid XHTML 1.0 Transitional
To Top of Page Top of Page

Copyright © Sealcon All Rights Reserved
|Domestic & International Cables|Enclosures |Liquid Tight Strain Relief Fittings & Accessories|
|Circular Connectors|Conduit System|Pneumatics|Cable Index|Enclosure Index|Search|
|Media|Site Map|Company Overview|Contact|Privacy Policy|Copyright Notice|