Page 5 - Power Cables
P. 5
i!I), HI·TECH (800) 877-8842 I (303) 880-5159 www_hltechcontrols_com
~ CONTROLS, INC. Click or Call for a Quotel
N 2X CY power cable 0.6/1 kV. with concentric conductor, VDE approved
~ N2XCY voe 0,6/1 kV CE
I RoHS I
Technical Data Cable Structure Properties
.. Power and control cable according to .. Bare copper conductor, single-wire • Self-extinguishing and flame retardant
DIN VDE 0276 Part 603 or according to DIN VDE 0295 d. 1, in accordance with VDE 0482-332-1-2.
HD 603 51 and lEe 60502 B5 6360 cI. 1, lEe 60228 or HD 383 DIN EN 60332-1-2/ lEe 60332-1
7 cores and above in accordance • Core insulation from cross-linked (conforms to DIN VDE 0472 Part 804
with DIN 0276 Part 627 or polyethylene compound, DIX3 Test method B)
HD 627 51 and lEe 60502 according to HD 603.1 • The materials used in manufacture are
.. Temperature range • Cores stranded in concentric layers free of silicone. cadmium and sub-
Flexing -SoC to + SOO( • Filling compound stances that impair paint wetting
0
Fixed installation _400( to + 70 e • Concentric conductor, inner layer of Highest permissible voltage
.. Permissible operat ing te mpe rature round bare copper wires, outer layer • Direct current systems 1.8 kV
0
at the conductor + 90 ( of copper tape as counter helix • Three-phase systems
• Permissible short circuit • PVC outer sheath. DMV6 according Single-phase systems
temperature +250 ( (short- to HD 603.1 Both outer conductors insulated 1.4 kV
0
circuit duration 5 sec.) • Sheath colour - black Single-phase systems
.. Nominal voltage One outer conductor earthed 0.7 kV
U<lU 0.611 kV • Three-phase system 1.2 kV
.. Test voltage 4 kV
Max. permissible t ensile load Notes
with cable grip = 50 N/mm2 • re = round conductor. single-wire;
.. Minimum bending radius rm = round conductor. multi-wire;
Single-core approx. 1 5x cable 0" sm = sector-shaped conductor.
Multi-core approx. 12x cable 0" multi-wire.
Application
Power distribution cables for industrial applications and switching systems. residential connections and street lighting,
as well as control cables for transmitting control pulses and measurements. Wherever increased electrical and
mechanical protection are required. For installation underground, in water, outdoors. indoors. in concrete and
cable ducts. Respecting the permissible operating temperature at the conductor of + 90°C permits a higher current
carrying capacity than PVC insulated power distribution cables.
The concentric conductor (C) can be used as a PE or PEN conductor or as a screen.
(( ~ The product conforms to the EG Low-Voltage Directive 2006/9S/EG
Pilrt No Number of cores" Outer" Cop. Weight Weight
Nominal cross-se<:tion mm '9I'<m appro,.,
mm' 'g/I<m
ll212 2~I,5 reJI ,5 !l.0 205
ll2!l 2x2,5 re(2,S !l,S " no
80
ll214 2~4 rrd4 15,5 360
l321S 2~6 reJ6 17,0 '"
590
ll216 2~ 1 0 re{10 19,5 '" '"
l3217 2~16 rell6 20.5 '" 820
'"
l3218 ld,5 rell,S !l,S 66 m
l3219 l~2,5 re(2,5 14,5 290
ll220 l~4 rel4 16,5 '''' "0
'"
ll221 l x6 reJ6 17,5 2" "0
l3222 l~ I O rellO 20,0 "S 850
ll2H lx16re{16 23.0 "3
l2224 l,,25 rnv'16 25,1 902 ""
1295
!l75
ll225 3x25 rm/25 25.0 '0'" , .. ,
ll226 lll3S $m/16 25.1
1402
ll227 ld5 smll5 25,4 "" 1619
33228 l~50 sm/2S 27.l 172l '''2
ll229 l,,50 sm/SO 27.7 2000 2107
llHO l,,70 $mIlS 32,2 2410 noo
llH I 3~70 snv'70 32,7 2796
3588
llH2 lll95 )m/SO 35.l 3296 ""
o.m.r.........nd spoofiut.,.,. n-.y be d>on!tod .... Ihoul PI'''' nota
II: HELUKABEL