Page 2 - Power Cables
P. 2

i!I), HI·TECH                               (800) 877-8842 I  (303) 880-5159           www_hltechcontrols_com
  ~ CONTROLS, INC.                               Click or Call for a  Quotel

                                                                                                             ~
    NAVCWY power cable 0.6/1 kV,  with concentric conductor,                                                 MEOI
   VOE approved













     I RoHS I


   Technical Data                          Cable Structure                         Properties
    •  Power and control cable according to  •  Aluminium conductor according to   • pvc self-extinguishing and flame
      DIN  VDE  0276 Part 603 or             DIN  VDE  0295 cI. 1, lEe 60228,        retardant in accordance with
      HD 603 51  and  lEe 60502              85 6360 cl.  1 or HD 383               VDE  0482-332-1 -2,
                                                         2
    •  Temperature range                   · 16 to 35 mm ,  round conductor          DIN  EN  60332-1-2/ lEe 60332-1
                        0
      Flexing -SoC to + 50 (                 Single-wire (re) or 50-240 mm2,        (conforms to DIN VDE  0472  Part 804
      Fixed  installation  _400(  to + 70 e   sector-shaped conductor,              Test method B)
                                   0
    •  Permissible operating temperature     si n9 Ie-wi re (se)                   • The materials used  in  manufacture are
     at conductor + 70 e                   •  PVC core insulation, DIV4 in          free of silicone, cadmium and sub-
                      0
    •  Permissible short-circuit             accordance with HD 603.1               stances that impair paint wetting
                         0
     temperature  + 160 (  (short-circuit   • Core colour according to             Highest permissible voltage
     duration 5 sec.)                        DIN  VDE  0293-308 or HD  186         •  Direct current systems  1.8 kV
    •  Nominal voltage Uc/U 0.611  kV      •  Cores stranded in concentric layers   • Three-phase systems
    •  Test voltage 4 kV                   •  Filling compound                      Single-phase systems:
    •  Max.  permissible tensile load      • Concentric conductor, inner layer       Both outer conductors insulated  1.4 kV
     with cable grip =  30  N/mm2            Corrugated (Ceander),  round,          Single-phase systems:
    •  Minimum bending radius                Bare copper wires,  outer layer        One outer conductor earthed 0.7  kV
     Approx. 12x cable 0                     Copper tape as counter helix          • Three-phase system  1.2 kV
                                           •  PVC outer sheath,  DMVS according     with concentric conductor and
                                             to HD 603.1                            a cross-section from 240 mm 3.6 kV
                                                                                                                2
                                           •  Sheath colour - black
                                                                                   Note
                                                                                   •  re  =  round conductor,  single-wire;
                                                                                    se  =  sector-shaped conductor,  single-
                                                                                    wire.

   Application
   Power cable,  preferably used  for underground installation, primarily in  local  networks,  for industrial applications and
    switching systems,  power stations. Wherever increased  electrical and mechanical protection are required.  Installation
   in water, outdoors,  in concrete,  indoors and in  cable ducts. The concentric conductor (C)  can  be used  as a PE  or PEN
   conductor or as  a screen. The corrugated design (Ceander) of the concentric conductor permits any number of cable
   junctions during assembly,  without any conductors having to be cut. This guarantees optimised  reliability.
   (€ =  The product conforms to the EG  low-Voltage Directive 2006/95/EG
    Part No.        Number of (ores.            Outer 0           Cop. Wei9ht        Alu weight         Weight
                    nominal ( ross sectio n     mm                '''''m             appro • .          appro • .
                    mm'                                                              '''''m             '''''m
    32840               4.1(; re/16             21,~                                                      12~0
                                                                                      '"
    32841               4x2~ re/16              2~,~              '"                  29O                 1800
    32842              4x3~ sl1"\l16            21,1              '"                                      20~0
    32843              4.~0 snv;!5              28,2              '"                  '"                  "00
                                                                  167
                                                                                      580
                                                                                      81.
    "'"                4. 10 sm/35              32.3              '"                 1102                 3150
                                                                  '"
                                                35,8
                                                                                                          5000
                       4. 95 sm/50
    32845
    32846              4.120 sm;70              39,2                                 1392                 6350
    32847              4.150 sm;70              43,2              '"                 1740                 76~0
                                                                  <73
    32848              4.185 smJ95              48,4              639                2146                 9350
    32849              4x240 sm/120             56,0              800                ,,8<                11600
   ~ Ind opK'flUt.",. moy be ct.."9fd ... thout 11"0' nota
                                                       I:  HELUKABEL