Page 3 - Power Cables
P. 3
i!I), HI·TECH (800) 877-8842 I (303) 880-5159 www.hltechcontrols.com
~ CONTROLS, INC. Click or Call for a Quotel
NA2XV power cable O.6/1kV. VDE approved
I RoHSI
Technical Data Cable Structure Properties
• Power and control cable according to • Aluminium conductor according to • Self-extinguishing and flame retardant
DIN VDE 0276 Part 603 Sl or HD 603.1 DIN VDE 0295 d. 1 or cl. 2, in accordance with VDE 0482-332-1-2,
and lEe 60502 single·wire or multi·wire, DIN EN 60332-1-2/ IEC 60332-1
- Temperature range BS 6360 cl. 1 or d. 2, IEC 60228 (conforms to DIN VDE 0472 Part 804
Flexing -5·C to + 50·C cl. 1 or d. 2 or HD 383 Test method B)
0
Fixed installation _400( to + 70 ( • Core insulation from cross-linked • The materials used in manufacture are
• Permissible operating temperature polyethylene compound, DIX3 in free of silicone, cadmium and sub-
0 accordance with HD 603.1
at the conductor +90 ( stances that impair paint wetting
• Permissible short circuit • Cores stranded in concentric layers Highest permissible voltage
temperature +250 ( (short-circuit • Core colours according to • Direct current systems 1.8 kV
0
duration 5 sec.) DIN VDE 0293-308, 0276 Part 603 • Three-phase systems
• Nominal voltage or HD 186 Single-phase systems:
UJ U O.61t kV • PVC outer sheath, DMV6/DMP2 Both outer conductors insulated 1.4 kV
• Test voltage 4 kV according to HD 603.1 Single-phase systems:
Max. permissible tensile load - Sheath colour - black One outer conductor earthed 0.7 kV
with cable grip = 30 N/mm2 • Three-phase system 1.2 kV
• Minimum bending radius Notes
Single-core approx. 15x cable 0
• re = round conductor, single-wire;
Multi-core approx. 12x cable 0
rm = round conductor, multi-wire;
sm = sector-shaped conductor,
multi-wire.
Application
Power distribution cables for use underground, in water, outdoors, in concrete, indoors, in cable ducts, for power
stations, industrial applications and switching systems, as weJl as in local networks if no mechanical damage is
expected. Respecting the permissible operating temperature at the conductor of + 90°C permits a higher current
carrying capacity than PVC insulated power distribution cables.
«( = The product conforms to the EG Low-Voltage Diredive 2006/95/EG.
Number Outer" Alu weight Weight J .• type O·type
of (ores ~ mm 'g/1<m appro~ . Part No. Part No.
nominal (ross 'g/1<m
se<:tion mm'
hl6re 11,5 47 98 33113 33125
lx25rm 12.5 "0 33114 33126
h35rm 13.5 " 33115 33127
'"
h50rm 15,5 '" '" 331 16 33128
357
h10rm 11,0 203 33111 33129
lx95rm 19,0 '" 33118 33130
"0
H'
hl20rm 20.5 '" 590 331 19 33131
1x150rm 23,0 435 804 33120 33132
'"
hl85rm 25,5 m 33121 33133
h240rm 28,5 '96 1253 33122 33134
IKlOOrm 30,0 870 03" 33123 33135
Ix400rm 34,0 1160 "90 33124 33136
'"
4~16rm 21 ,5 7" 33137 33147
4x25rm 26.0 290 950 33138 33148
4Kl5rm 21,5 406 1120 33139 33149
4x50sm 30,0 580 1251 33140 33150
4~70sm 34.0 ." 33141 33151
4x95sm 39.0 1102 "" 33142 33152
2030
4KI20sm 42.5 1392 2400 33143 33153
4KI50sm 41,5 1740 3030 33144 33154
4KI85sm 52.0 2146 3650 33145 33155
4K240sm 58.0 2784 4800 331 46 33156