Your One-Stop Solution For Cable & Wire Accessories!

RoHS Compliant Cable & Wire
Control Cable - Intrinsically Safe Cable


Contact Us About Us  
 
LinkedIn Facebook Twitter Hi Tech Controls Blog google +
Cables & WiresEnclosures (Plastic & Metal)Pneumatic ComponentsLiquid Tight Strain Relief FittingsCircular ConnectorsConduit System (Tubing, Fittings, etc.)Accessories & Adapters, Reducers, Enlargers
 
easyquote
*E-mail
*Name
*Company
*Phone
*State
*Zip Code
*Country
Please answer the security question:
3+2=
(*) Required Fields
Catalogs / Samples, Full Quote & Contact Information
303-699-1135
1-800-456-9012
dropdownbox
PDF Printable PDF

Control Cable: OB-BL-PAAR-CY

Outer Jacket Blue, Intrinsic Safety, EMI Preferred Type

Sealcon, Inc, European & Domestic cable

Sealcon, , European   OB-BL-PAAR-CY, EMC (EMI Preferred Type), Blue Outer Jacket, Intrinsic Safety, Intrinsically Safe Cable
Part-No. Description & No. Conductors x cross-sec. mm2 Outer
Diameter
mm
Copper weight
kg/km
Weight
ca. kg/km
AWG
14077 OB-BL-PAAR-CY 2X2X0.5 7.8 47.0 89.0 20
14078 OB-BL-PAAR-CY 3X2X0.5 8.2 67.0 104.0 20
14079 OB-BL-PAAR-CY 4X2X0.5 9.0 80.0 126.0 20
14080 OB-BL-PAAR-CY 6X2X0.5 10.6 108.0 171.0 20
14081 OB-BL-PAAR-CY 8X2X0.5 12.3 129.0 251.0 20
14082 OB-BL-PAAR-CY 10X2X0.5 13.5 172.0 282.0 20
14083 OB-BL-PAAR-CY 12X2X0.5 14.4 235.0 261.0 20
14084 OB-BL-PAAR-CY 16X2X0.5 16.3 301.0 445.0 20
14085 OB-BL-PAAR-CY 20X2X0.5 17.7 343.0 525.0 20
14086 OB-BL-PAAR-CY 24X2X0.5 19.3 394.0 590.0 20
14087 OB-BL-PAAR-CY 25X2X0.5 19.7 406.0 622.0 20
14089 OB-BL-PAAR-CY 2X2X0.75 8.4 60.0 105.0 18
14090 OB-BL-PAAR-CY 3X2X0.75 9.0 80.0 128.0 18
14091 OB-BL-PAAR-CY 4X2X0.75 9.8 110.0 156.0 18
14092 OB-BL-PAAR-CY 6X2X0.75 12.1 142.0 216.0 18
14093 OB-BL-PAAR-CY 8X2X0.75 13.4 200.0 309.0 18
14094 OB-BL-PAAR-CY 10X2X0.75 15.1 238.0 355.0 18
14095 OB-BL-PAAR-CY 12X2X0.75 15.8 270.0 405.0 18
14096 OB-BL-PAAR-CY 16X2X0.75 18.0 342.0 560.0 18
14097 OB-BL-PAAR-CY 20X2X0.75 19.2 369.0 671.0 18
14098 OB-BL-PAAR-CY 24X2X0.75 21.3 451.0 795.0 18
14099 OB-BL-PAAR-CY 25X2X0.75 21.8 461.0 803.0 18
Technical Data
  • Special PVC control cable with blue outer jacket for hazardous areas to hazard type -i- for intrinsically safe installation according to DIN EN 60079-14 and IEC 60079-14 section 12.2.2 (VDE 0165 part 1)
  • Conductor Resistance
    At 0.5 mm² 37.8 Ohm/km
    At 0.75 mm² 25.3 Ohm/km
  • Temperature Range
    Flexing -5°C to +80°C
    Fixed Installation -30°C to +80°C
  • Nominal Voltage 900 V
    (not for power installation)
  • Test Voltage
    Conductor/conductor 2000 V
    Conductor/shielding 1000 V
  • Breakdown Voltage min. 4000 V
  • Insulation Resistance
    Min. 20 MOhm x km
  • Mutual Capacitance
    Conductor/conductor approx. 105 nF/km
    Conductor/shielding approx. 145 nF/km
  • Inductance
    Approx. 0.68 mH/km
  • Characteristic Impedance
    Approx. 80 Ohm
  • Minimum Bending Radius
    Flexing 10x cable Ø
    Fixed Installation 5x cable Ø
  • Radiation Resistance
    Up to 80x106 cJ/kg (up to 80 Mrad)
  • Coupling Resistance
    Max. 250 Ohm/km
Approvals
RoHSCE PCT RoHS
Cable Construction  
  • Bare copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5
  • Special PVC conductor insulation YI2, to DIN VDE 0207 part 4
  • Conductors color coded according to DIN 47100
  • Conductors twisted in pairs
  • Pairs stranded in layers with optimal lay-length
  • Foil taped
  • Tinned copper braided shielding, approx. 80% coverage
  • Special PVC outer jacket YM2, to DIN VDE 0207 part 5
  • Color blue RAL 5015
Application  

For hazardous areas this flexible control cable has been constructed for closed circuit systems in accordance with VDE 0165 part 1, part 12.2.2.6, which covers the requirements for the special marking (blue) (hazard type-i-). The paired construction and the copper shielding afford a good protection against electrical interference and ensure the transmission of data signals.
EMI = Electromagnetic Interference
To optimize the EMI features we recommend a large round contact of the copper braiding on both ends.
CE Approval = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.

Properties  
  • Extensively oil resistant
    Chemical Resistance - see table Technical Information
  • PVC self-extinguishing and flame retardant according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
  • The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Note  
  • AWG sizes are approximate equivalent values. The actual cross-section is in mm².
Cable Accessories  
  • Coming Soon!
Cable Technical Data Construction and ApplicationProperties and Note Accessories
quote
Items For Quote

   
quote
box
Intrinsically Safe Cables
OZ-BL
OZ-BL-CY
OB-BL-PAAR-CY
box
Sealcon is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135 FAX: 303-680-5344
Valid XHTML 1.0 Transitional
To Top of Page Top of Page

Copyright © Sealcon All Rights Reserved
|Domestic & International Cables|Enclosures |Liquid Tight Strain Relief Fittings & Accessories|
|Circular Connectors|Conduit System|Pneumatics|Cable Index|Enclosure Index|Search|
|Media|Site Map|Company Overview|Contact|Privacy Policy|Copyright Notice|