303-680-5159
1-800-677-8942
Hi-Tech Controls European Harmonized Cable: THREENORM
PVC Single Conductors, UL Style 1011 and CSA 600 V
PVC single conductors to
DIN VDE 0281 part 3, HD 21.3 S3
UL Style 1011 and CSA, CSA-AWM
|/A/B
Temperature Range
H05 V-K / H07 V-K
Flexible
-5°C to +70°C (+23°F to +158°F)
Fixed Installation
-10°C
to +70°C (+14°F to +158°F)
UL/CSA +80°C/+176°F
Nominal Voltage
H05 V-K U0 /U 300/500
V
H05 V-K U0 /U 450/750
V
UL/CSA 600 V AC
Test Voltage
H05 V-K / H07 V-K 2000 V
Spark Test
AWG 20: 5 kV
> AWG 20: 6 kV
Insulation Resistance
Min. 20 MOhm x km
Minimum Bending Radius
For permanent bending
Ca. 10-15 x conductor Ø
H05 V-K
Cross-Sec.
mm2 / AWG
Outer
Dia.
Copper
Weight
kg/km
European Part-No.
black
blue
brown
red
white
gray
violet
pink
RAL
9005
RAL
5015
RAL
8003
RAL
3000
RAL
1013
RAL
7000
RAL
4005
RAL
3015
0.5
/ 20
2.5
4.8
63815
63817
63818
63819
63820
63821
63822
63824
0.75
/19
2.65
7.2
63831
63833
63834
63835
63836
63837
63838
63840
1.0
/ 17
2.8
9.6
63847
63849
63850
63851
63852
63853
63854
63856
Cross-Sec.
mm2 /
AWG
Outer
Dia.
Copper
Weight
kg/km
European Part-No.
orange
green
yellow
green-yellow
2-colored
dark
blue
transp.
no
color
RAL
2003
RAL
6018
RAL
1021
-
-
RAL
5010
-
-
0.5
/ 20
2.5
4.8
63828
63825
63823
63816
63830
63827
63826
63829
0.75
/19
2.6
7.2
63844
63841
63839
63832
63846
63843
63842
63845
1.0
/ 18
2.8
9.6
63860
63857
63855
63848
63862
63859
63858
63861
H07 V-K
Cross-Sec.
mm2 /
AWG
Outer
Dia.
Copper
Weight
kg/km
European Part-No.
black
blue
brown
red
white
gray
violet
pink
RAL
9005
RAL
5015
RAL
8003
RAL
3000
RAL
1013
RAL
7000
RAL
4005
RAL
3015
1.5
/ 16
3.05
14.4
63863
63865
83866
63867
63868
63869
63870
63872
2.5
/ 14
3.6
24.0
63879
63881
63882
63883
63884
63885
63886
63888
4.0
/ 12
4.1
38.0
63895
63897
63898
63899
63900
63901
63902
63904
6.0
/ 10
4.8
58.0
63911
63913
63914
63915
63916
63917
63918
63920
10.0
/ 8
6.4
96.0
63927
63929
63930
63931
63932
63933
63934
63936
16.0
/ 6
8.1
154.0
63943
63945
63946
63947
63948
63949
63950
63952
25.0
/ 4
9.6
240.0
63959
63961
63962
63963
63964
63965
63966
63968
35.0
/ 2
10.8
336.0
63975
63977
63978
63979
63980
63981
63982
63984
50.0
/ 1
13.6
480.0
63991
63993
63994
63995
63996
63997
63998
64000
70.0
/ 2/0
15.2
672.0
64007
64009
64010
64011
64012
64013
64014
64016
95.0
/ 3/0
16.8
912.0
64023
64025
64026
64027
64028
64029
64030
64032
120.0
/ 4/0
19.5
1152.0
64039
64041
64042
64043
64044
64045
64046
64048
150.0
/
300 kcmil
22.2
1440.0
64055
64057
64058
64059
64060
64061
64062
64064
Cross-Sec.
mm2 /
AWG
Outer
Dia.
Copper
Weight
kg/km
European Part-No.
orange
green
yellow
green-yellow
2-colored
dark
blue
transp.
no
color
RAL
2003
RAL
6018
RAL
1021
-
-
RAL
5010
-
-
1.5
/ 16
3.05
14.4
63876
63873
63871
63864
63878
63875
63874
63877
2.5
/ 14
3.6
24.0
63892
63889
63887
63880
63894
63891
63890
63893
4.0
/ 12
4.1
38.0
63908
63905
63903
63896
63910
63907
63906
63909
6.0
/ 10
4.8
58.0
63924
63921
63919
63912
63926
63923
63922
63925
10.0
/ 8
6.4
96.0
63940
63937
63935
63928
63942
63939
63938
63941
16.0
/ 6
8.1
154.0
63956
63953
63951
63944
63958
63955
63954
63957
25.0
/ 4
9.6
240.0
63972
63969
63967
63960
63974
63971
63970
93673
35.0
/ 2
10.8
336.0
63988
63985
63983
63976
63990
63987
63986
63989
50.0
/ 1
13.6
480.0
64004
64001
63999
63992
64006
64003
64002
64005
70.0
/ 2/0
15.2
672.0
64020
64017
64015
64008
64022
64019
64018
64021
95.0
/ 3/0
16.8
912.0
64036
64033
64031
64024
64038
64035
64034
64037
120.0
/ 4/0
19.5
1152.0
64052
64049
64047
64040
64054
64051
64050
64053
150.0
/
300 kcmil
22.2
1440.0
64068
64065
64063
64056
64070
64067
64066
64049
Bare copper fine wire stranded
to DIN VDE 0295 cl.5, BS 6360 cl.5,
HD 383 and IEC 60228 cl.5
UL Subject 758 Section G resp.
ASTM B 174
PVC conductor insulation T|1 to
DIN VDE 0281 part 1 and UL-Std. 1581,
class 43, CSA-C 22.2 No. 210 Tab.
12 class H
Conductor colors to DIN VDE 0293
PVC self-extinguishing and flame
retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1
(equivalent DIN VDE 0472 part 804
test method B) UL-VW1 CSA FT1
The materials used in manufacture
are cadmium-free, contain no silicone
and are free from substances harmful
to the wetting properties of lacquers
Tinned conductor on request
AWG sizes are approximate equivalent
values. The actual cross-section is
in mm2 .
The cross-sections 0.5 mm2 ,
0.75 mm2 and 1.0 mm2 are
acc. to H05 V-K, the cross-sections
1.5 to 120 mm2 acc. to
H07 V-K
Three
norms approved connecting
jumper wire primarily designed
for export, used in machine
tools. This wire is used
for internal wiring of switchboards
and electrical equipment.
The approbation of HAR-UL-CSA
AWM make an economical store
keeping and simplification
of part lists possible.
=
The product
is conformed
with the EC
Low-Voltage
Directive 73/23/EEC
and 93/68/EEC.
Items For Quote
Update Easy Quote
is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.