European Medium Voltage Power Cable: NYY-J / NYY-O

Power Cable, 0.6/1 kV, VDE Approved

Sealcon, Inc, European & Domestic cable

NYY-J / NYY-O power cable, 0.6/1 kV, VDE approved, RoHS compliant, Medium Voltage Power Cables, Power & Underground Cables, Earth Conductors, Sealcon, European
No. of Conductors
1
1
2
2
3
3
4
4
5
5
7
7
10
10
12
12
14
14
16 16 19 19 21 21 24 24 30 30 40 40 52 52 61 61
3 + 1/2 conductors
3 + 1/2 conductors
European
Part-Numbers
Description & No. Conductors x cross-sec. mm2 Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
J-type O-type
32001 32089 NYY-J / NYY-O 1X4 re 9.0 38.0 115.0 12
32002 32090 NYY-J / NYY-O 1X6 re 9.5 58.0 135.0 10
32003 32091 NYY-J / NYY-O 1X10 re 10.0 96.0 179.0 8
32004 32092 NYY-J / NYY-O 1X16 re 11.0 154.0 245.0 6
32005 32093 NYY-J / NYY-O 1X25 rm 12.0 240.0 360.0 4
32006 32094 NYY-J / NYY-O 1X35 rm 13.0 336.0 470.0 2
32007 32095 NYY-J / NYY-O 1X50 rm 15.0 480.0 620.0 1
32008 32096 NYY-J / NYY-O 1X70 rm 16.5 672.0 810.0 2/0
32009 32097 NYY-J / NYY-O 1X95 rm 19.0 912.0 1110.0 3/0
32010 32098 NYY-J / NYY-O 1X120 rm 20.5 1152.0 1360.0 4/0
32011 32099 NYY-J / NYY-O 1X150 rm 22.5 1440.0 1670.0 300 kcmil
32012 32100 NYY-J / NYY-O 1X185 rm 25.0 1776.0 2050.0 350 kcmil
32013 32101 NYY-J / NYY-O 1X240 rm 28.0 2304.0 2630.0 500 kcmil
32014 32102 NYY-J / NYY-O 1X300 rm 30.0 2880.0 3200.0 600 kcmil
32015 32103 NYY-J / NYY-O 1X400 rm 34.0 3840.0 4150.0 750 kcmil
32556 32558 NYY-J / NYY-O 1X500 rm 38.0 4800.0 5200.0 1000 kcmil
32557 32559 NYY-J / NYY-O 1X630 rm 43.0 6048.0 6650.0 -

32016 32104 NYY-J / NYY-O 2X1.5 re 11.0 29.0 175.0 16
32017 32105 NYY-J / NYY-O 2X2.5 re 12.0 48.0 215.0 14
32018 32106 NYY-J / NYY-O 2Xx4 re 14.0 77.0 295.0 12
32019 32107 NYY-J / NYY-O 2X6 re 15.0 115.0 370.0 10
32020 32108 NYY-J / NYY-O 2X10 re 16.5 192.0 495.0 8
32021 32109 NYY-J / NYY-O 2X16 re 18.5 307.0 670.0 6
32022 32110 NYY-J / NYY-O 2X25 rm 23.5 480.0 960.0 4

European
Part-Numbers
Description & No. Conductors x cross-sec. mm2 Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
J-type O-type
32023 32111 NYY-J / NYY-O 3X1.5 re 11.5 43.0 195.0 16
32024 32112 NYY-J / NYY-O 3X2.5 re 12.5 72.0 250.0 14
32025 32113 NYY-J / NYY-O 3X4 re 14.0 115.0 340.0 12
32026 32114 NYY-J / NYY-O 3X6 re 15.0 173.0 430.0 10
32027 32115 NYY-J / NYY-O 3X10 re 17.0 288.0 590.0 8
32028 32116 NYY-J / NYY-O 3X16 re 19.0 461.0 820.0 6
32029 32117 NYY-J / NYY-O 3X25 rm 24.0 720.0 1320.0 4
32030 32118 NYY-J / NYY-O 3X35 sm 25.0 1008.0 1450.0 2
32031 32119 NYY-J / NYY-O 3X50 sm 26.5 1440.0 1850.0 1
32032 32120 NYY-J / NYY-O 3X70 sm 30.0 2016.0 2450.0 2/0
32033 32121 NYY-J / NYY-O 3X95 sm 34.5 2736.0 3300.0 3/0
32034 32122 NYY-J / NYY-O 3X120 sm 37.0 3456.0 4100.0 4/0
32293 32296 NYY-J / NYY-O 3X150 sm 40.0 4320.0 4900.0 300 kcmil
32294 32297 NYY-J / NYY-O 3X185 sm 46.0 5328.0 6500.0 350 kcmil
32295 32298 NYY-J / NYY-O 3X240 sm 51.0 6912.0 8300.0 500 kcmil

32044 32132 NYY-J / NYY-O 4X1.5 re 12.0 58.0 230.0 16
32045 32133 NYY-J / NYY-O 4X2.5 re 13.5 96.0 300.0 14
32046 32134 NYY-J / NYY-O 4X4 re 15.0 154.0 410.0 12
32047 32135 NYY-J / NYY-O 4X6 re 16.5 230.0 520.0 10
32048 32136 NYY-J / NYY-O 4X10 re 18.5 384.0 730.0 8
32049 32137 NYY-J / NYY-O 4X16 re 21.5 614.0 1045.0 6
32050 32138 NYY-J / NYY-O 4X25 rm 26.0 960.0 1640.0 4
32051 32139 NYY-J / NYY-O 4X35 sm 27.5 1344.0 1760.0 2
32052 32140 NYY-J / NYY-O 4X50 sm 30.0 1920.0 2350.0 1
32053 32141 NYY-J / NYY-O 4X70 sm 34.0 2688.0 3100.0 2/0
32054 32142 NYY-J / NYY-O 4X95 sm 39.0 3648.0 4250.0 3/0
32055 32143 NYY-J / NYY-O 4X120 sm 42.5 4608.0 5300.0 4/0
32056 32144 NYY-J / NYY-O 4X150 sm 47.5 5760.0 6400.0 300 kcmil
32057 32145 NYY-J / NYY-O 4X185 sm 52.0 7104.0 8500.0 350 kcmil
32058 32146 NYY-J / NYY-O 4X240 sm 58.0 9216.0 11000.0 500 kcmil

European
Part-Numbers
Description & No. Conductors x cross-sec. mm2 Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
J-type O-type
32059 32147 NYY-J / NYY-O 5X1.5 re 13.0 72.0 270.0 16
32060 32148 NYY-J / NYY-O 5X2.5 re 14.5 120.0 360.0 14
32061 32149 NYY-J / NYY-O 5X4 re 16.5 192.0 490.0 12
32062 32150 NYY-J / NYY-O 5X6 re 18.0 288.0 600.0 10
32063 32151 NYY-J / NYY-O 5X10 re 20.0 480.0 890.0 8
32064 32152 NYY-J / NYY-O 5X16 re 22.5 768.0 1255.0 6
32065 - NYY-J / NYY-O 5X25 rm 28.0 1200.0 1960.0 4
32300 - NYY-J / NYY-O 5X35 rm 34.0 1680.0 2400.0 2
32257 - NYY-J / NYY-O 5X50 rm 40.0 2400.0 3500.0 1

32066 32153 NYY-J / NYY-O 7X1.5 re 15.5 101.0 310.0 16
32076 - NYY-J / NYY-O 7X2.5 re 16.5 168.0 450.0 14
32086 - NYY-J / NYY-O 7X4 re 18.5 269.0 640.0 12
32087 32174 NYY-J / NYY-O 7X6 re 20.0 403.0 850.0 10
32088 32175 NYY-J / NYY-O 7X10 re 23.5 672.0 1200.0 8

32067 32154 NYY-J / NYY-O 10X1.5 re 18.0 144.0 380.0 16
32077 - NYY-J / NYY-O 10X2.5 re 19.5 240.0 520.0 14

32068 32155 NYY-J / NYY-O 12X1.5 re 19.0 173.0 420.0 16
32078 - NYY-J / NYY-O 12X2.5 re 20.5 288.0 600.0 14

32069 32156 NYY-J / NYY-O 14X1.5 re 20.0 202.0 470.0 16
32079 - NYY-J / NYY-O 14X2.5 re 21.0 336.0 680.0 14

32070 32157 NYY-J / NYY-O 16X1.5 re 21.0 230.0 520.0 16
32080 - NYY-J / NYY-O 16x2.5 re 22.0 384.0 750.0 14

European
Part-Numbers
Description & No. Conductors x cross-sec. mm2 Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
J-type O-type
32071 32158 NYY-J / NYY-O 19X1.5 re 22.0 274.0 570.0 16
32081 - NYY-J / NYY-O 19X2.5 re 23.0 456.0 850.0 14

32072 32159 NYY-J / NYY-O 21X1.5 re 23.0 302.0 650.0 16
32082 - NYY-J / NYY-O 21X2.5 re 24.5 504.0 980.0 14

32073 32160 NYY-J / NYY-O 24X1.5 re 25.0 346.0 750.0 16
32083 - NYY-J / NYY-O 24X2.5 re 27.0 576.0 1100.0 14

32074 32161 NYY-J / NYY-O 30X1.5 re 26.0 432.0 860.0 16
32084 - NYY-J / NYY-O 30X2.5 re 28.0 720.0 1280.0 14

32075 32162 NYY-J / NYY-O 40X1.5 re 29.0 576.0 1070.0 16
32085 - NYY-J / NYY-O 40X2.5 re 31.5 960.0 1700.0 14

32169 - NYY-J / NYY-O 52X2.5 re 35.0 1248.0 2150.0 14

32176 - NYY-J / NYY-O 61X1.5 re 34.0 878.0 1680.0 16
3 + 1/2 conductors
European
Part-Numbers
Description & No. Conductors x cross-sec. mm2 Outer
Diameter
Copper Weight
kg/km
Weight
ca. kg/km
AWG
J-type O-type
32035 32123 NYY-J / NYY-O 3X25 / 16 rm 24.5 874.0 1530.0 4
32036 32124 NYY-J / NYY-O 3X35 / 16 sm 26.0 1162.0 1750.0 2
32037 32125 NYY-J / NYY-O 3X50 / 25 sm 29.0 1680.0 2350.0 1
32038 32126 NYY-J / NYY-O 3X70 / 35 sm 32.0 2352.0 2850.0 2/0
32039 32127 NYY-J / NYY-O 3X95 / 50 sm 38.0 3216.0 3850.0 3/0
32040 32128 NYY-J / NYY-O 3X120 / 70 sm 41.0 4128.0 4780.0 4/0
32041 32129 NYY-J / NYY-O 3X150 / 70 sm 46.0 4992.0 5800.0 300 kcmil
32042 32130 NYY-J / NYY-O 3G185 / 95 sm 51.0 6240.0 7600.0 350 kcmil
32043 32131 NYY-J / NYY-O 3X240 / 120 sm 58.0 8064.0 9800.0 500 kcmil
32256 - NYY-J / NYY-O 3X300 / 150 sm 64.0 10080.0 11500.0 600 kcmil
Technical Data European
  • Power and control cable to DIN VDE 0276 part 603, HD 603.1 and IEC 60502, 7-conductor and above to DIN VDE 0276 part 627, HD 627 S1 and IEC 60502
  • Temperature Range
    Flexing
    -5°C to +50°C (+23°F to +122°F)
    Fixed Installation
    -40°C to +70°C (-40°F to +158°F)
  • Permissible Operating Temperature
    at conductor +70°C/+158°F
  • Permissible Short Circuit Temperature
    +160°C/+320°F (short circuit duration 5 sec.)
  • Nominal Voltage U0/U 0.6/1 V
  • Test Voltage 4 kV
  • Max. permissible Tensile Stress with cable grip for copper conductor = 50 N/mm2
  • Minimum Bending Radius (Approx.)
    For single conductor 15 x cable Ø
    For multi conductor 12 x cableØ
  • Power Ratings
    See Technical Information
  • Caloric Load Values
    See Technical Information
Code-Designation for Power Cables with PVC or XLPE Insulation
Design Identification of Design Explanations
Conductor N According to VDE Standard
(No abbreviation for copper conductor)
A Aluminum conductors
Y Insulation of thermoplastic Polyvinyl chloride (PVC)
2X Insulation cross-linked Polyethylene (XLPE)
Concentric Conductor, Shielding C Concentric conductors of copper wires and copper tape, helically wounded
CW Concentric conductors of copper wires in wave conal formation and and copper tape, helically wounded
CE Concentric conductors of copper wires and copper tape over each individual conductor, helically wounded
Shielding S Shielding of copper wires and copper tape, helically wounded
SE Shielding of copper wires and copper tape over each individual conductor, helically wounded
(F) Longitudinally water-proof shielding
Armor B Armor of steel tape
F Armor of galvanized flat steel wires
G Counter helix of galvanized steel tape
Jacket K Lead jacket
Outer Jacket Y PVC jacket
2Y PE jacket
Cable for U0/U 0.6/1 kV are additionally designated with
  -J Cables with green-yellow (green-natural) conductor are marked with protective conductor
-O Cables without green-yellow (green-natural) conductor are marked without protective conductor
Approvals
RoHSVDE
Cable Construction  
  • Plain copper conductor, to DIN VDE 0295 cl. 1 or cl. 2 solid or stranded type, BS 6360 cl. 1 or cl. 2, IEC 60228 and HD 383
  • PVC conductor insulation, DIV4 to HD 603.1
  • Conductors stranded concentrically
  • Color coded to DIN VDE 0293-308, 0276 part 603 or HD 186
  • Conductor color for 3+1/2 conductor
    J-type: green-yellow (1/2), brown, black, gray
    O-type: blue (1/2), brown, black, gray
  • PVC outer jacket, DMV5 to HD 603.1
  • Jacket color: Black
Application  
Power cables for energy supply are installed outdoors, in underground, in water, indoors, in cable ducts, power stations, for industry and distribution boards as well as in subscriber networks, where mechanical damages are not to be expected.
CE Approval = The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Properties  
  • PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
  • The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Highest permissible voltage
  • Direct current systems 1.8 kV
  • Alternating current systems,
    single-phase systems 1.4 kV
    Both conductors insulated,
    single-phase systems 0.7 kV
    One conductor grounded,
    three-phase systems 1.2 kV
    With concentric conductor and
    a cross-section of 240 mm²
    and above 3.6 kV

Note  
  • re = round conductor, single wire
    rm = round conductor, multiple wires
    sm = stranded, sectional conductor
  • Also available in NYFGBY, NYBY versions etc.
  • 2 conductors = adapted to DIN VDE
  • In respect to 3 + 1/2 conductors
    Whereby only one conductor is allowed to contain a smaller cross section (as per DIN VDE 0276 part 603 table 5) and permitted to place as insulated conductor (green-yellow and blue as 1/2 conductors) stranded in layers.
Cable Accessories  
  • Coming Soon!
Cable Technical Data Construction and ApplicationProperties and Note Accessories
quote
Items For Quote

   
quote
box
Power Cables up to 30 kV, XLPE-Insulated
NYY-J / NYY-O
NAYY-J
NYCY
NYCWY

A-LiY(St)YÖ

Earth Conductors ESUY & ESY
box
 
Sealcon is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135 FAX: 303-680-5344
Valid XHTML 1.0 Transitional
To Top of Page Top of Page

Copyright © Sealcon All Rights Reserved
|Domestic & International Cables|Enclosures |Liquid Tight Strain Relief Fittings & Accessories|
|Circular Connectors|Conduit System|Pneumatics|Cable Index|Enclosure Index|Search|
|Media|Site Map|Company Overview|Contact|Privacy Policy|Copyright Notice|