Page 10 - Cables According to International Approvals
P. 10

i!I), HI·TECH                               (800) 877-8842 I  (303) 880-5159           www_hltechcontrols_com
  ~ CONTROLS, INC.                               Click or Call for a  Quotel

                                                                                                             ~ I·I
   TRAVCONTROL 300-C TP  stranded pair.  flexible.
   screened. oil-resistant. EMC preferred type,  NFPA 79 Edition 2007











    I RoHS I

   Technical Data                          Cable Structure                        Properties
   ..  Flexible screened  PVC data and     ..  Tinned copper conductor,  fine wire   •  Self-ext inguishing and flame retardant
     control cable                           stranded, with AWG measures            in accordance with CSA FT4
   •  Tem perature  ra n ge                  Special  PVC core insulation         ..  The materials used  in manufacture are
     -2S"C to +' 05"C                        (AWG 22 - AWG  18 with                 free of silicone,  cadmium and sub-
   •  No minal volta g e  300 V              transparent nylon skin)                stances that impair paint wetting
   •  Test  voltage 2000 V                   Pair identification according to     ..  Test s
   ..  M in imum b ending  radius            international colour code;             UL (AWG 22 - AWG  18):  PLTC-ER.
     Flexing  6x cable 0                     see next page                          ITC-ER,  CM, NFPA 79 2007,
   ..  Co u pling  resist a n ce            AWG 26 - AWG 22                         OIL RES  I &  II, Class I Div.  2, NEC Art .
     Max. 250 Ohm/km                        AWG20-AWG18                             501,725,  760 &  800, AWM 2464
                                             Cores stranded in pairs with           Ul (AWG 24 - AWG 26):CM, AWM
                                             optimal lay-length                     2464, rated OIL RES  I &  II,
                                             Pairs stranded in  layers with         NEC Art. 725, 760 & 800,  NFPA 79
                                            optimal lay-length                      2007
                                           •  , . Screening with special            CSA : CSA CMG FT4,  AWM VII  AlB
                                            aluminium foil
                                             2. Screening with braid of           Notes
                                             tinned copper wires, optimal
                                            coverage, approx. 85%                 Advantages
                                                                                  ..  Highly-flexible. easy to install
                                             Separator
                                                                                  •  Oil-resistant to all RES  I &  II
                                           •  Special  PVC outer jacket
                                           •  Sheath colour - grey (RAL 7001)     Ava ilable  o n  request
                                           •  With length marking in feet         ..  PUR or TPE  outer sheath
                                                                                  •  Sheath colour to suit customer
                                                                                    requirement
   Application
   HELUKABEl® TRAYCONTROl 300-C TP is a screened, stranded  pair data and control cable.  Cross-sections with  PLTC-
   ER  and  ITC-ER  approval suitable for open,  unprotected installation in cable trays to t he  machine; their outstanding oil
   resistance (Oil RES  I &  II)  makes them  ideally suited as connecting  and joining cables and also for control, signal and
   measuring systems in industrial plants. The flexible cable strudure facilitates installation  inside and  outside of machines
   and switch cabinets. The double-screening  wit h aluminium foil (100% coverage) and copper braid (approx. 85% co-
   verage) guarantee superior EMC protection. Applications: tool machines,  control panels,  measuring devices,  production
   automation, cable ducts,  renewable energies.
   EMC =  Electromagnetic compatibility.
   To optim ise EMC charaderistics,  we recommend a  large con tad area for t he copper braiding around the entire
   circumference on  both  ends.
   ( € =  The product conforms to the EG  Low-Voltage Directive 2006/ 95/EG
    Part No.   Number of   Outer"   Cop. Weight   Weigh!         Part No.   Number of   Outer '"   Cop. Weigh!   Weigh!
             pairs      appro ...   ''''m        appro ...               pairs      .. ppro •.   ''''m        appro • .
                        mm                                                           mm
                 ,
                                                                              ,
    26 AWG I  0.14 mm'  (19/38)   .,             '""m            24 AWG I 0.25 mm'  (19/36)   .. ,            '""m
    61999        ,                                               59777        ,      ...
    59760        ,           ,  ..    "           "              59778        ,      ,.,           "           "
    59761                    "        "           "              59779                            "            "
    59762        •  ,        ,.,      "           "              59780        •  ,   .. ,         "            "  ,.
                                                                                     ",
    59763        ,           "        "           "              59781        ,                   "            "
    59764        ,           ,  ..    "           "              59782        ,      ••  .. ,     "           , "
                             ",
    59765                    , ..     "           "              59783               ..,          "
    59766        •           ,.,      "           "              59784        •                   "           '"
                                                                                                              '"
                                                                                                              m
    59767                    ,.       "           "              59785               11 .4        "  ",       .. ,
    59768       "                     "           '"             59786       "       11.8
                                                                             "
                "
    59769       "            10.5     "           '"             59787       "       12.6         '"
                                      "
                                                                                                              m
                             11 .1
    59770       ..           11.8  ..             '"  ".  ,,,    59788       ..      12.8         '"          '"
    59771       "            11.2     "                          59789       "       12.9         '"          m
    59772       "                     "  ,.                      59790       "       13.8         '"          no
    59773                    12.4                 '"             59791               14.4         '"          no
                                                                             ,.
                                                                                                  '"
    59774       "            13.1    '"           '"             59792       "       15.3         '"          , ..
                                                 ".
    59775       "            13.6                '"              59793       "       16.4         no          '"
    59776       "            15.1    '"  ".      ",              59794               16.7                     '"
                "
   Two-<",,~_ .... _' NM """ •. no, fA-- ~ _   ~ro""",.-. ~~ ... u-.. 1""" no'",~   "             '"              Con ....... ,"'" ..
                                                       IC  HELUKABEL
   5   6   7   8   9   10   11   12   13   14   15