Page 27 - New Products 2010
P. 27
i!I), HI·TECH (800) 877-8842 I (303) 880-5159 www_hltechcontrols_com
~ CONTROLS, INC. Click or Call for a Quotel
TRAVCONTROL 600 flexible, oil-resistant,
TRAY CABLE for open installation TC-ER, PLTC-ER, ITC-ER, NFPA 79 Edition 2007
-
~ _ i
1<' , - ~ELUKA8Et til TAAVCONTROt 600 I' N I'!~ l' AWG (331"",,'Y4C (UllTC ER90C ORV?5CWrTOOtNSUN RES DU:t SUR OIt RES I
lL.(1103CSAAWI.IIL!A,'B'.lOCGOOVFT4 CE ROHS
E3304300RMTW"FtEXINO'ORWTTC1OOOVORcIUlICICTCPVCNFT4
I RoHS I
Technical Data Cable Structure Properties
• PVC power cable according to • Bare copper conductor, fine wire • Self-extinguishing and flame retardant
UL 1277 stranded with AWG dimensions material in accordance with (SA FT4
• Temperature range • Special PVC core insulation with • The materials used in manufacture are
U l/CSA TC -40°C to + 90°C transparent nylon skin free of silicone, cadmium and sub-
ULI AWM -40°C to + 90°C • Black cores with continuous white stances that impair paint wetting
• Nominal voltage numbering • UV-resistant
TC 600 V • Green-yellow earth core in the • Tests
AWM 1000V outer layer, 3 cores and more UL: TC-ER, PLTC-ER (AWG 18 - AWG
WTTC 1000 V • Cores stranded in layers with 12), ITC-ER (AWG 18 - AWG 12), UL
• Test voltage optimal lay-lengths 1277, UL TypeWTTC, UL Type MTW
3000 V • Separator NFPA 79 2007, Oil Res I (Oil Res II also
• Minimum bending radius • Special PVC outer jacket available), 90° C dry 175° C wet
Approx. 5x cable 0 • Sheath colour - black (RAL 9005) CSA:
• Insulation resistance • With length marking in feet c (UL) ClC-TC FT4
Min. 20 MOhm x km CSA AWM VII Al8 FT4
• Radiation resistance
Up to 80xl 0' cJ/kg (up to 80Mrad) Advantages Notes
• TC-ER, Tray Cable Exposed Run • G = with green-yellow earth core
• Simple installation • X = without earth core (02)
• Outstanding flexibility
Application
USA NFPA79, Edition 2007 compliant flexible power cables to 600 V (WTTC 1000 V), for all machinery in tool and plant
construction, suitable for installation in dry, damp and wet environments, outdoors and in pipes. For underground
installat ion and for open, unprotected installat ion from the cable tray to the machine and industrial plants.
(E ~ The product conforms to the EG Low-Voltage Directive 2006/95/EG.
Part No. Number of Outer" Cop. Weight Weight Part No. Number of Outer" Cop. Weight Weight
cores approlC. kglkm approlC. cores apprOK. kglkm apprOK.
mm kglkm mm kglkm
18AWG/ l mm' (I 9/JO) 16 AWG / l .32 mm' (26/30)
62902 1 " , .. 6292 1 1 ' .5 15 80
"
62903 , 19 " 62922 , ' .8 38 86
88
3
3
61904 8.' 39 62921 8.5 51
"
62905 , 8.' 48 ." 62924 , 9.3 63 "'
5
5
130
62906 9.3 ." 62925 10.0
86
lB'
62907 9 10.7 " .,. 62926 7 10.1 " '"
lB.
89
62908 10 11 .6 96 62927 8 10.9 ' 01 101
62909 11 11.9 115 150 62928 9 11.7 .14 138
62910 13.2 14' 191 62929 10 12.4 m 159
62911 " 13.3 ." 306 62930 11 12.9 m ".
lB
62912 " 14.6 m 365 62931 14 14.5 In 365
62913 14.7 lB1 384 62932 15.0 m
'"
15
62914 " 17.0 140 48' 62933 " 15.2 103 405
62915 17.4 159 511 62934 " 15.9 118
lB
34
62916 " 19.3 316 615 62935 16.0 141 '"
".
62917 19.8 355 684 62936 " 16.5 153 '50
10
62918 " 20.7 394 74'
41
62919 50 23.5 '80 933
"
62920 24.9 586 '095
lwcK"",,- ",\haul ",Ih COft. no! ER. DIrntn\.IOn. _ ~r .... !JOM ~ ~ <hMIg«I WI\hau\ poor nohc~ Con\lroUll\"", ..
I: HELUKABEL