Control Cable: Single 602-RC* -J/-O

RoHS/Deca BDE
Single-602-RC

https://www.hitechcontrols.com/cables/control_cable/pvc/single_602_rc_j_o.html

Special Single Conductor Cable for Drag Chains/Track Cable, +90°C/ +194°F, 600 V *RC = Robotics Cable

Cable Construction

  • Bare copper, extra fine wire conductors to DIN VDE 0295 cl
  • Conductor insulation of special PVC, TI3 to DIN VDE 0281
  • Conductor insulation (jacket) of special PVC,
  • UL-Style 10107, Color: Black (RAL 9005)

Properties

  • For Chemical Resistance
  • Resistant to mineral oils, synthetic oils and lubricating coolants
  • PVC self-extinguishing and flame retardant according
  • Cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

 

MULTISPEED® 500-PVC UL/CSA

PVC Control Cable for Drag Chain/TrackMULTISPEED_500-PVC_UL


 

 

 

https://www.hitechcontrols.com/cables/control_cable/drag_pvc/multispeed_500_pvc_ul_csa.html

High Flexible, Safety Against High Bending in Drag Chain/Track Cable Systems, Low Torsion, Low Torsion, EMI Preferred Type

Application:

UL/CSA approved HELUKABEL® MULTISPEED 500-PVC are installed where the extreme requirements for the cables are necessary. Designed for the export-orientated machinery manufacturer, specifically for USA and Canada. The selected materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and slow speed of movements.
These high flexible PVC control cables are suitable for shift and bending stresses in machines and machine tool constructions. These are installed in dry and moist rooms with free movement without tensile stress or forced movements.

Properties:

• PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) VW1, FT1
• Low-adhesion High property of alternating bending strength
• Long life durability due to low friction-resistance
• Better chemical resistance
• Oil resistance High stability Higher economical solution
• Reduced Ø, results low weight of moving materials
• The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Control Cable: JZ-603

JZ-603-THREENORM

UL-CSA-HAR approved cables
https://www.hitechcontrols.com/cables/control_cable/pvc/jz_603.html
Flexible, 3 Approvals Control Cable (THREENORM), RoHS, Deca BDE

  • Oil resistant as per HD/EN 60811-2-1, UL 1581 part 50.182
  • PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
  • The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
  • Bare copper, fine wire conductors
  • Special PVC conductor insulation TI1
  • Black conductors with white continuous numbering, Green-yellow grounding in the outer layer

Control Cable: JZ-600-Y-CY UL/CSA

Flexible, Number Coded, 0.6/1kV, Copper-Shielded, EMI Preferred Type

JZ-600-Y-CY_UL_CSA

https://www.hitechcontrols.com/cables/control_cable/pvc_shielded/jz-600_y_cy_ul_csa.html

Application:

Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burial or as underwater cable. Interference-free transmission of signals and pulses is assured by the high degree of shielding.
EMI = Electromagnetic Interference
To optimize the EMI features we recommend a large round contact of the copper braiding on both ends.

Properties

  • Extensively oil resistant
  • For chemical resistance, see table Technical Information
  • Resistant to ultra violet rays (building with black jacket)
  • PVC self-extinguishing and flame retardant according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) VW1, FT1
  • The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Cable Construction

  • Bare copper, fine wire conductors according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5
  • Special PVC conductor insulation TI2, to DIN VDE 0281 part 1, class 43 UL Std. 1581
  • Black conductors with sequential numbering imprinted in white, according to DIN VDE 0293
  • Green-yellow earth conductor in the outer layer (3 conductors and above)
  • Conductors stranded in layers with optimal lay-length
  • PVC-insulated inner jacket TM2, to DIN VDE 0281 part 1, class 43 UL-Std. 1581
  • Braided shielding of tinned copper wires, coverage approx. 85%
  • Special PVC outer jacket TM2, to DIN VDE 0281 part 1 class 43 UL Std. 1581
  • Color: Black (RAL 9005) or Gray (RAL 7001)

Technical Data

  • Special PVC control cables
  • Adapted to DIN VDE 0276 part 627, DIN VDE 0281 part 13, with insulation thickness for 1 kV type and UL Std. 758 Style 21179
  • Temperature Range: Flexing -5°C to +80°C (+23°F to +176°F), Fixed Installation -40°C to +90°C (-40°F to +194°F)
  • Nominal voltage U 1000 V
  • Test voltage 4000 V
  • Breakdown voltage min. 8000 V
  • Insulation Resistance Min. 20 MOhm x km
  • Power Rating According to DIN VDE 0298
  • Minimum Bending Radius Flexing 10x cable Ø, Fixed Installation 5x cable Ø
  • Radiation Resistance Up to 80×106 cJ/kg (up to 80 Mrad)
  • Coupling Resistance Max. 250 Ohm/km

Control Cable: JZ-600 UL/CSA

JZ-600_UL_CSA
https://www.hitechcontrols.com/cables/control_cable/pvc/jz_600_ul_csa.html

Flexible, Number Coded, 0.6/1kV, UL & CSA Approved, AWG: 20 – 4, RoHS, Deca BDE, Extensively oil resistant For Chemical Resistance, see table Technical Information Resistant to ultra violet rays (building with black jacket), PVC self-extinguishing and flame retardant, cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers.

JZ-500-HMH (Halogen Free)PVC Control Cable

JZ-500-HMH-Halogen Free https://www.hitechcontrols.com/cables/halogen_free_security_cables/control/jz_500_hmh.html

• Flexible Control Cable, Halogen-Free, Extremely Fire Resistant, Oil Resistant
• Halogen-free flexible control cable, adapted to E DIN VDE 0281 part 14 …and DIN VDE 0281 part 13
• Temperature Range: Flexing -15°C to +70°C (+5°F to +158°F), Fixed Installation
-40°C to +70°C (-40°F to +158°F)
• Nominal Voltage U0/U 300/500 V
• Test Voltage 2000 V
• Minimum Bending Radius: Flexing approx. 12.5x cable Ø, Fixed Installation approx. 4x cable Ø
• Radiation resistance: Up to 100×106 cJ/kg (up to 100 Mrad)
• Applications: tool machines, coveyor belts, production lines in machinery production, air-conditioning, steel production

Clean Room approved

TRAYCONTROL 500 flexible and oil-resistant control cable

For open installation TC-ER, PLTC-ER, ITC-ER, NFPA 79 Edition 2007

Traycontrol-500
https://www.hitechcontrols.com/cables/control_cable/pvc/traycontrol-500.html

Application

HELUKABEL® TRAYCONTROL 500 is a flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this cable to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 Edition 2007. Approved for open, unprotected installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life for industrial applications in dry, damp and wet environments.

Recommended applications: production lines, bottling plants, machine construction, switch cabinets, conveyor systems, packaging machines, automotive industry.

CE = The product conforms to the EG Low-Voltage Directive 2006/95/EG

Technical Data

• PVC control cable according to UL Standard 1277

• Temperature range: Flexing -5°C to +90°C / Fixed installation -40°C to +90°C

• Nominal voltage: TC 600 V, AWM: 1000 V, TC Wind Turbine (WTTC): 1000V, Test voltage 3000 V

• Minimum bending radius: Flexing 4x cable Ø

• Insulation resistance: Min. 20 MOhm x km

• Radiation resistance: Up to 80×106 cJ/kg (up to 80 Mrad)

Cable Structure

• Bare copper conductor, fine wire stranded

• Special PVC core insulation with transparent nylon skin

• Black cores with continuous white numbering

• Green-yellow earth core in the outer layer, 3 cores and more

• Cores stranded in layers with optimal lay-lengths

• Separator

• Special PVC outer jacket

• Jacket/Sheath color – grey (RAL 7001)

• With length marking in feet

Properties

• Self-extinguishing and flame retardant in accordance with CSA FT4

• The materials used in manufacture are free of silicone, cadmium and substances that impair paint wetting

• Tests

UL: TC-ER, PLTC-ER (AWG 18 – AWG 12), ITC-ER (AWG 18 – AWG 12), MTW, NFPA 79 2007, WTTC 1000V, DP-1, OIL RES I & II, 90°C dry / 75°C wet, Class 1 Div. 2 per NEC Art 336, 392, 501, crush impact test in accordance with UL 1277

CSA: c(UL) CIC-TC FT4, CSA AWM I/II A/B FT4

Servo, Feedback & Motor Cables

Servo VFD MotorA multitude of applications needs the inset of particular special cable constructions. Corresponding to the customer’s requirements those cables may be constructed with different stranding elements and cross-sections of the cable. In this case we are speaking about combination or hybrid cables. Application technical reasons may require using different insulating materials, choosing special stranding types or special shielding, for example multiple or mixed shielding.

https://www.hitechcontrols.com/cables/servo_cable/selection_pages/servo_feedback_motor_selection.html

Intrinsically Safe Cable, Control Cable: OZ-BL-CY

OZ-BL-CY-Intrinsic-Safety
Outer Jacket Blue, Intrinsic Safety, Flexible, EMI Preferred Type

https://www.hitechcontrols.com/cables/control_cable/intrinsic_safe/oz_bl_cy.html

Application:

For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus. These installations are not grounded and require a separate power circuit. Those cables are not suitable for underground laying.
The copper braided shielding ensures the transmission of data signals and free from interference.
EMI = Electromagnetic Interference
To optimize the EMI features we recommend a large round contact of the copper braiding on both ends.
CE= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC

Cable Construction

  • Bare copper, fine wire conductors bunch stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5
  • Conductor insulation of special PVC Z 7225
  • Black conductors with white continuous figure imprint to DIN VDE 0293 without ground conductor
  • Conductors stranded in layers with optimal lay-length
  • Conductor wrapping of plastic foil
  • Braiding, tinned copper wire shielding, approx. 85% coverage
  • Special PVC outer jacket TM2, to DIN VDE 0281 part 1 and HD 21.1
  • Color: Blue (RAL 5015)

Properties

  • Extensively oil resistant
    Chemical Resistance – see table Technical Information.
  • PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
  • The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Technical Data

  • Control cable, special PVC with blue outer jacket for hazardous areas to hazard type -i- (=intrinsically safe)
  • For intrinsically safe installation marking as per DIN EN 60079-14 and IEC 60079-14 section 12.2.2 (VDE 0165 part 1)
  • Temperature Range Flexing -5°C to +80°C (+22°F to +176°F), Fixed Installation  -40°C to +80°C (-40°F to +176°F)
  • Nominal Voltage U0/U 300/500 V
  • Test Voltage 3000 V
  • Breakdown Voltage min. 6000 V
  • Insulation Resistance Min. 20 MOhm x km
  • Mutual Capacitance Conductor/conductor approx. 140 nF/km, Conductor/screen approx. 187 nF/km
  • Inductance approx. 0.68 mH/km
  • Coupling Resistance Max. 250 Ohm/km
  • Minimum Bending Radius Flexing 10x cable Ø Fixed Installation 5x cable Ø
  • Radiation Resistance Up to 80×106 cJ/kg (up to 80 Mrad)\