Your One-Stop Solution For Cable & Wire Accessories!

Enclosures (Plastic and Metal)
D, K & KF Series Enclosure


Contact Us Site Map  
 
Follow us:  LinkedIn Facebook Twitter Hi Tech Controls Blog google +
Cables & WiresEnclosures (Plastic & Metal)Pneumatic ComponentsLiquid Tight Strain Relief FittingsCircular ConnectorsConduit System (Tubing, Fittings, etc.)Accessories & Adapters, Reducers, Enlargers
 
easyquote
*Email
*Name
*Company
*Phone
*Address
*City
*State
*Zip Code
*Country
Please answer the security question:
3+2=
(*) Required Fields
Catalogs / Samples, Full Quote & Contact Information
Quote Request 303-680-5159
1-800-677-8942
Contact Information, Phone
dropdownbox

IMPORTER OF
Helukabel Cables & Wires
WE PROVIDE CUSTOMERS WITH CABLE MANAGEMENT SOLUTIONS!
-Quantity Discounts! -No Minimum Orders! -Inventory in Excess of $25 Million!
-Blanket Orders! -Quick and Friendly Service! -All Major Credit Cards!
Loading
Enclosure Home Page|Industrial Enclosures|Thermoplastic Enclosures w/ Metric Knockouts & Terminals


K 2401 - Thermoplastic Enclosures w/ Metric Knockouts & Terminals

K 2405, Liquid Tight Polycarbonate Enclosure (Indoor Installation), from 4- 500 MCM AWG 3 phase, 5-pole, with Terminal Block Dimensions: (W) 17.72"(450) x (H) 11.81"(300) x (D) 6.69"(170)
  Enlarge Picture

K 2405, Liquid Tight Polycarbonate Enclosure (Indoor Installation), from 4- 500 MCM AWG 3 phase, 5-pole, with Terminal Block Dimensions: (W) 17.72"(450) x (H) 11.81"(300) x (D) 6.69"(170)
Enlarge Picture

 

Reference to the preparation of aluminum conductors:
  1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!).
  2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal.
  3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again.
  4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
rated connecting capacity 3~ 35-240 mm
conductor material: Prior to connection, aluminium conductors must be prepared according to the relevant technical recommendations. Cu/Alu
Polarity 5-pole, per pole
conductor cross section 4 x 35-240 mm
conductors are inserted into the screw-type terminal, terminal technology, see annex DK Cable junction boxes
conductor cross section Cu/Alu, sol (round) 2 x 25-50 mm
Cu/Alu, s / f (round) 2 x 25-240 mm
Cu/Alu, sol (sector) 2 x 50-185 mm
Cu, s (sector) 2 x 35-240 mm
conductor cross section Alu, s (sector) 2 x 95-185 mm
Cu/Alu, sol (round) 4 x 25-50 mm
Cu/Alu, s / f (round) 4 x 25-120 mm
Cu/Alu, sol (sector) 4 x 50-120 mm
conductor cross section Cu, s (sector) 4 x 35-120 mm
Alu, s (sector) 4 x 50-95 mm
current carrying capacity of the terminal 850 A
rated insulation voltage AC/DC 690 V
degree of protection: IP 65
material: thermoplastic
color: gray RAL 7032
cable entry via Metric Knockouts, see accessories

Accessories Accessories
Detailed Dimensions Detailed Dimensions
Hole Configuration: Hole Configuration: Number of Holes and Sizes

K2401 Features & Applications

Cable junction box K 2401
Application area Suitable for indoor installation and outdoor installation, protected against weather influences according to DIN VDE 0100 Part 737
Resistant to occasional cleaning procedures (direct jet) Resistant to occasional cleaning procedures (direct jet) with high-pressure cleaner without additives, water pressure: max. 100 bar, water temperature: max. 80 C, distance => 0,15 m, in accordance with the requirements IP 69K, enclosure and cable glands at least IP 65
ambient temperature Average value over 24 hours + 35 C
Maximum value + 40 C
Minimum value - 25 C
Relative humidity 50% at 40 C short-time 100% at 25 C
Fire protection in the event of internal faults Demands placed on electrical devices from standards and laws Minimum requirements - Glow wire test in accordance with IEC 60 695-2-11: - 650C for boxes and cable glands - 850C for parts of insulating material necessary to retain current carrying parts in position
Fire protection in the event of specific risks or hazards Demands placed on electrical installations and devices in areas and facilities subject to fire risk, e.g. DIN VDE 0100 Part 482, official regulations, VdS directives Minimum requirements - Glow wire test to IEC 60 695-2-11: - 850C for boxes and cable glands - 850C for cavity wall installation - Use of fire resistant cables
Burning behavior Glow wire test IEC 60 695-2-11: 960 C
UL Subject 94 V-2
flame resistant self-extinguishing
degree of protection against mechanical load IK08 (5 Joule)
Toxic behavior halogen-free silicone-free "halogen-free" in accordance with the examination of the cables and insulated wires - corrosiveness of fumes - as per IEC 754-2
Note: To material properties see technical data.

Our products are used in the following areas of application: 

  • Companies involved in the processing of metal, wood and paper, cement factories
  • Agricultural and food industries
  • Water treatment and sewage plants, power stations and cold-storage depots
  • Banks and insurance buildings
  • Leisure and commercial centers
  • Hotel and cinema complexes
  • Hospitals and clinics
  • Schools and universities
  • Stadiums and sports centers
  • Gas stations and traffic infrastructure in ports, underground stations, tunnel and road construction
  • Indoor and outdoor installations
quote
Items For Quote

   
quote
box

Sealcon is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
Liquid Tight Strain Relief, Cord Grips, Cable Gland FittingsLiquid Tight Strain Relief Fittings, Cord Grips, Cable Glands
Threads: PG, NPT, Metric, BSPP Threads
Materials: Nylon, Nickel Plated Brass, PVDF (for chemicals and extreme temperatures) & Stainless Steel, NEMA 4x and 6 (IP68, IP 69K).
Approvals: RoHS, Deca BDE, UR, UL, CE, CSA, VDE, German Lloyd, etc.
UL f1 (UL 746C) - Suitable for outdoor use with respect to exposure to ultraviolet light, water exposure and immersion in accordance with UL 746C
Circular ConnectorsCircular Connectors (M16, M23, RJ45, M27 and M40)
Sizes: M16 Signal, M23 Signal & Power, M27 Signal, M40 Power, M12/16 Twintus
Types: Twintus, RJ45 Industrial Ethernet, PoE Fast Ethernet, Push-Pull, Stainless Steel, Over Molded Cordsets, Standard/EMI Ready
Configurations: Signal (3-28 pole) & Power (6 & 8 pole)
Materials: Nickel Plated Brass, Stainless Steel and Aluminum
Approvals: RoHS, Deca BDE, UR, UL, CSA, TÜV, etc.
Hummel EnclosuresIndustrial Enclosures (Plastic & Metal)
Materials: Polycarbonate, ABS (Acryl-Butadiene-Styrene), Aluminum, Steel/Stainless Steel and Polyester.
Types: Gray or Transparent Lids, available with Hinges and Latches, Plain Walls or Knockouts.
Approvals: RoHS, Deca BDE, UL, CSA, TUV and CE. Modular, Expandable, UV and Impact Resistant, NEMA 4, 4x (IP 66/67). Solar Plus for Photovoltaic applications.
Our Enclosures can be equipped with Strain Relief Fittings, Circular Connectors or Conduit Fittings. Other customization options like cutting & drilling are also available.
Conduit SystemConduit System
High Pull-Out Resistance, Robust Performance, Long Life Expectancy, Fastest/ Easy installation, No Tools required!
Fittings:
Push-In, Turn-to-Seal, Snapclic DUO (Nylon or Nickel Plated Brass), Double-Seal, Flange/Bulkhead
Conduit:
Standard and Super Flex Corrugated Conduit
Accessories: Snap-In Mounting Brackets. NEMA 4 (IP 54/65)
Approvals: RoHS, Deca BDE, UR, German Lloyd, CE, etc.
Hazardous Location / Explosive Proof Cord Grips, Cable GlandsHazardous Location / Explosive Proof Cord Grips, Cable Glands
These fittings are labeled and approved to withstand the required needs of a combustible environment.
Materials: Nylon, Nickel Plated Brass, PVDF (chemical resistant & extreme temperatures), Stainless Steel.
Threads: NPT, Metric & PG. NEMA 4x (IP 67) and 6 (IP 68/69K)
Approvals:
RoHS, Deca BDE, UL, CSA, VDE, CE, EEx e, ATEX, German Lloyd, IECEx,
Ex-d/Ex-e, Ex-i
EXIOS - High-end Cable Glands for armored cables in hazardous areas including the latest IECEx and ATEX certifications, for use in Ex-e, Ex-d and Ex-tD areas
Adapters, Enlargers, ReducersThread Adapters, Enlargers, Reducers
Convert, Increase or Decrease your thread size with our newest product line of Adapters, Enlargers and Reducers.
Threads: NPT, Metric and PG.
Materials: Black or Gray Nylon, Nickel Plated Brass, Aluminum, Stainless Steel.
Approvals: RoHS, Deca BDE, CE, EEe x, ATEX, etc.
Hazardous / Explosive proof versions available.
Cable AccessoriesCable Accessories
Locking Nuts:Black & Gray Nylon, Nickel Plated Brass, Zinc Plated Steel, EMI (w/ Cutting Edges)
O-Rings: Buna-N, Viton®, Silicone
Seal Rings: Polyethylene / Fiber-reinforced Plastic
Hole Plugs: Dome, Hex, Nylon, Nickel Plated Brass
Inserts: Standard, Reduced, Multi-Hole, Romex®
Other Accessories: Ratchet & Socket Wrenches, Cable Clamps, etc.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-677-8942 / 303-680-5159 FAX: 303-680-5344
Valid XHTML 1.0 Transitional
To Top of Page Top of Page

Copyright © 2012 Hi-Tech Controls Inc. All Rights Reserved
|Cables: Domestic & International|Enclosures (Plastic & Metal)|Liquid Tight Strain Relief Fittings & Accessories|
|Circular Connectors|Conduit System|camozzi Pneumatics|Cable Index|Enclosure Index|Search|
|Media|Site Map|Company Overview|Contact|Privacy Policy|Copyright Notice|