Code Designation for Harmonized Cables and Flexible Cords
(acc. to DIN VDE 0292 & HD 361 S2/S
This system of code-designation is prepared by CENELEC for harmonized cables as flexible cords for power installations and published in Harmonization Document 361 S3.
Code
Designation
Classified to Standards
H
Harmonized Standard
A
Authorized National Standard
Conductor Material
w/o
designation
Copper
- A
Aluminum
- Z
Conductor of special material and/or special shape
Type & Shape of Conductor
- D
fine wire stranded conductor for welding cables
- E
extra fine wire stranded conductor for welding cables
- F
fine wire stranded conductor for flexible cables according to DIN VDE 0295, class 5
- H
extra fine wire stranded conductor for flexible cables according to DIN VDE 0295, class 6
- K
fine wire stranded conductor for fixed installation (if not specified, equivalent to J DIN VDE 0295, class 5)
- M
Milliken conductor
- R
conductor of multi stranded wires
- S
sector-shaped conductor of multi stranded wires
- U
round conductor of single wire
- W
sector-shaped conductor of single wire
- Y
tinsel conductor
- Z
conductor of special material and/or special shape
Number of Conductors & Cross-section
Number
Number of conductors n
X
Multiplication sign without green-yellow ground conductor
G
Multiplication sign for green-yellow ground conductor
Y
Tinsel conductor, whereby the cross-section is not specified
Insulation and Jacket Material
B
Ethylene-propylene-rubber for Temperature of +90°C
B2
Ethylene-propylene rubber, hardened
B3
Butyl rubber (isobutylene-isoprene rubber)
E
Polyethylene
E2
Polyethylene, high density
E4
Polytetrafluorethylene
E5
Perfluor (Ethylene-propylene - copolymers)
E6
Ethylene-tetrafluorethylene - copolymers
E7
Polypropylene
G
Ethylene-vinylacetate - copolymers
J
Braiding of glass fiber
J2
Wrapping of glass fiber
M
Mineral insulation
N
Chloroprene-rubber (or equivalent material)
N2
Special compound of chloroprene-rubber
N4
Sulfonated chlor or chlorinated polyethylene
N5
Nitril-rubber
N6
Fluorinated rubber
N7
PVC-Nitril-rubber compound
N8
Special-polychloroprene-rubber, water resistant
P
Cables with impregnated paper insulation for multi conductor belted cable
Q
Polyurethane
Q2
Polyethyleneterephthalate
Q3
Polystyrole
Q4
Polyamide
Q5
Polyamide
Q6
Polyvinylidene fluoride
R
Ethylene-propylene rubber or equivalent
synthetic elastomer for +60°C temperature of
+60°C, for permanent temperature of +60°C
S
Silicone-rubber
T
Textile braiding over twisted conductors, impregnated/un-impregnated
T2
Textile braiding with flame retardant, impregnated composition
T3
Layer of textile as conductor wrapping or tape
T4
Layer of textile as conductor wrapping or tape with flame retardant impregnated composition
T5
Corrosion protection
T6
Textile braiding over individual conductor or multi conductor
cable, impregnated/un-impregnated
V
PVC soft
V2
PVC soft, resistant to increased temperature, +90°C
V3
PVC soft, for low temperatures
V4
PVC soft, cross-linked
V5
PVC soft, oil resistant
X
Cross-linked polyethylene
Z
Cross-linked compound to a basis of polyolefin, for low corrosive gas and low smoke emission in case of fire
Z1
Thermoplastic compound to a basis of polyolefin, for low corrosive gas and low smoke emission in case of fire
Metal Jacket
A2
Aluminum jacket, pressed or welded, smooth
A3
Aluminum jacket, pressed or welded, corrugated
A4
Aluminum jacket over individual conductor
A5
Aluminum jacket of Band
C2
Copper jacket
C3
Copper jacket, corrugated
F
Steel jacket
F3
Steel jacket, corrugated
K
Zinc jacket
L
Alloyed lead jacket for general use
L2
Non-alloyed lead jacket, normal pure lead
L4
Alloyed lead jacket over individual conductor
L5
Non-alloyed lead jacket over individual conductor
L6
Alloyed lead jacket, but other composition than above
Concentric Conductors
A
Concentric aluminum conductor
A6
Concentric aluminum conductor, meander-shaped
C
Concentric copper-conductor
C6
Concentric copper-conductor, meander-shaped
C9
Divided concentric copper conductor
Shielding
A7
Aluminum screen
A8
Aluminum screen of individual conductor
C4
Copper screen as braid over the stranded conductors
C5
Copper screen braiding over individual conductor
C7
Copper screen of tape, round or profile-wires over twisted conductors
C8
Copper screen as C7, over individual conductor
D
Screen of one or more thin steel tapes, laying direct over twisted conductors, in contact with a
stranded plain conductor
Armoring**
Z2
Armoring of round steel wires*, galvanized / non-galvanized
Z3
Armoring of flat steel wires*, galvanized / non -galvanized
Z4
Armoring of steel tape, galvanized / non -galvanized
Z5
Braiding of steel wires, galvanized / non -galvanized
Z6
Supporting braid of steel wires
Z7
Armoring of sectional steel wires
Y2
Armoring of round aluminum wires*
Y3
Armoring of flat aluminum wires*
Y5
Armoring of special materials
Y6
Armoring of steel wires and/or steel tape and copper wires
* counter helix, if specified
** see remarks DIN VDE 0292
Special Constructive Supporting Elements
D2
Supporting elements of textile or steel wires over cable conductor
D3
Textile supporting elements of one or more elements, stranded in the conductor of circular cable or placed in a flat cable
D4
Self-supporting cables and wires, where the conductor permits the strain-relieving function
D5
Central conductor element (not as supporting element), used for lift cable
D7
As D3, the supporting element however is connected externally
D8
As D7, however a section horizontal to the axis of the cable forming the number “8“
Special Versions
w/o
designation
Round cable construction
H
Flat type as separable cables with or without jacket
H2
Flat type of cables not separable
H3
Building Cable, flat webbed
H4
Multi conductor flat cable with one plain conductor
H5
Two or more single conductor stranded, non-jacket
H6
Flat cables according to HD 359 or EN 50214 with 3 or more conductors
is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands Threads: PG, NPT, Metric, BSPP Threads Materials: Nylon, Nickel Plated Brass, PVDF (for chemicals and extreme temperatures) & Stainless Steel,
NEMA 4x and 6 (IP68, IP 69K). Approvals: RoHS, Deca BDE, UR, UL, CE, CSA, VDE, German Lloyd, etc. UL f1 (UL 746C) - Suitable for outdoor use with respect to exposure to ultraviolet light, water exposure and immersion in accordance with UL 746C
Circular Connectors (M16, M23, RJ45, M27 and M40) Sizes: M16 Signal, M23 Signal & Power, M27 Signal, M40 Power, M12/16 Twintus Types: Twintus, RJ45 Industrial Ethernet, PoE Fast Ethernet, Push-Pull, Stainless Steel, Over Molded Cordsets, Standard/EMI Ready Configurations: Signal (3-28 pole) & Power (6 & 8 pole) Materials: Nickel Plated Brass, Stainless Steel and Aluminum Approvals: RoHS, Deca BDE, UR, UL, CSA, TÜV, etc.
Industrial Enclosures (Plastic & Metal) Materials: Polycarbonate, ABS (Acryl-Butadiene-Styrene), Aluminum, Steel/Stainless Steel and Polyester. Types: Gray or Transparent Lids, available with Hinges and Latches, Plain Walls or Knockouts. Approvals: RoHS, Deca BDE, UL, CSA, TUV and CE.
Modular, Expandable, UV and Impact Resistant, NEMA 4, 4x (IP 66/67). Solar Plus for Photovoltaic applications.
Our Enclosures can be equipped with Strain Relief Fittings, Circular Connectors or Conduit Fittings. Other customization options like cutting & drilling are also available.
Conduit System
High Pull-Out Resistance, Robust Performance, Long Life Expectancy, Fastest/ Easy installation, No Tools required!
Fittings: Push-In, Turn-to-Seal, Snapclic DUO (Nylon or Nickel Plated Brass), Double-Seal, Flange/Bulkhead
Conduit: Standard and Super Flex Corrugated Conduit Accessories: Snap-In Mounting Brackets. NEMA 4 (IP 54/65) Approvals: RoHS, Deca BDE, UR, German Lloyd, CE, etc.
Hazardous Location / Explosive Proof Cord Grips, Cable Glands
These fittings are labeled and approved to withstand the required needs of a combustible environment. Materials: Nylon, Nickel Plated Brass, PVDF (chemical resistant & extreme temperatures), Stainless Steel. Threads: NPT, Metric & PG. NEMA 4x (IP 67) and 6 (IP 68/69K)
Approvals: RoHS, Deca BDE, UL, CSA, VDE, CE, EEx e, ATEX, German Lloyd, IECEx,