Your One Stop Solution
For Cable & Wire Accessories!

RoHS Compliant Cables & Wires:
Technical Information

Cables & Wires: Domestic & international, RoHS Compliant
Cable: Domestic & InternationalEnclosures: Plastic & MetalLiquid Tight Strain Relief FittingsCircular Connectors (M16, M23 & M40)Conduit System (Fittings, Tubing, Etc.)Camozzi Pneumatics - Fittings and Flow Control Valves
 
 
Easy Quote
*E-mail
*Name
*Company
*Phone
*State
*Zip Code
*Country
(*) Required Fields
- or -
Catalogs / Samples, Full Quote & Contact Information
Quote Request 1-800-677-8942
Catalog & Samples
Contact Information, Phone
 
TECHNICAL INFORMATION
Copper and Aluminum Price Calculation Copper & Alu Price Calculation
Reference to DIN VDE Standards Reference to DIN VDE Standards
Harmonized Identification Harmonized Identification
Code Designations Code Designations
Conductor Diameters according to VDE 0295 (DIN EN 60228) Conductor Diameters and Resistance
Strand Make-up according to DIN VDE 0295, IEC 60228 & HD 383 Strand Make-up acc. to DIN VDE 0295, IEC 60228 & HD 383
Nominal & Operating Voltage Nominal & Operating Voltage
Current Carrying Capacity for Power Cables & Wires Current Carrying Capacity for Power Cables & Wires
Installation Methods & Operating Conditions Installation Methods & Operating Conditions
Laying Conditions for Power Cables Laying Conditions for Power Cables
Current Ratings for Installation Current Ratings for Installation
Color Codes Color Codes
Bending Radius & Chemical Resistance Bending Radius & Chemical Resistance
Heat Resistance & Caloric Load Values Heat Resistance & Caloric Load Values
Installation Instructions for UL and CSA Cables  Installation Instructions for UL and CSA Cables
AWG Wires & AWG Stranded Conductors AWG Wires & AWG Stranded Conductors
US and British Units - Conversions US and British Units - Conversions
Current Ratings for UL-CSA Cables Current Ratings for UL-CSA Cables
List of UL-Styles List of UL-Styles
Index British Standard Index British Standard
International Abbreviations International Abbreviations
Characteristics of Insulating and Jacket Materials Characteristics of Insulating and Jacket Materials
Definitions: Classes of Stress in Flexible Cables and Insulated Wires Definitions: Classes of Stress in Flexible Cables and Insulated Wires
Safety Requirements Safety Requirements
Glossary of Terms: Cables & Wires Glossary of Terms: Cables & Wires
International Certification Marks & Testing Institute International Certification Marks & Testing Institute
Formulas of Electronic & Power Engineering Formulas of Electronic & Power Engineering
Cable-Drums - Capacity & Cable Lengths Cable-Drums - Capacity & Cable Lengths
Notes on CE-Marking Notes on CE-Marking
European Directives European Directives
TECHNICAL INFORMATION - OVERVIEW
View Technical Information - Index View Technical Information - Index

THE EXCLUSIVE IMPORTER OF
Helukabel Cables & Wires

We Provide Customers With Cable Management Solutions!
- Quantity Discounts!
- No Minimum Orders!
-Inventory in Excess of $25 Million
-Accept: All Major Credit Cards!
- Blanket Orders!
- Quick & Friendly Service!

Reference to DIN VDE Standards

Power Installations
DIN VDE 0100 - Regulations for Power Installations w/ rated voltages below 1000V
DIN VDE 0100 part 100 - General requirements, scope
DIN VDE 0100 part 410

- Protective measures and protection against electric shock

DIN VDE 0100 part 430

- Protection of cables against over-current

Supplement 1 to part 430

- Recommended values for current-carrying capacity

DIN VDE 0100 part 482

- Choice of protective measures, protection against fire

DIN VDE 0100 part 520/530

- Selection and set-up of equipment - cable, wires & wiring systems
- Set-up of electrical equipment - switch- and control gear

DIN VDE 0100 part 559

- Luminaries and lighting equipment

DIN VDE 0100 part 701 - 705

- Rooms containing a bath tub or shower basin
- Roofed & open-air swimming pools
- Rooms containing electrical sauna-heater - Installation-site
- Agricultural and horticultural premises

DIN VDE 0100 part 720

- Fire-hazardous locations

DIN VDE 0100 part 726 - 738 - Lifting and hoisting devices
- Laying of cables in hollow walls and in buildings made up mainly   of flammable building materials
- Cable entries into buildings in public cable network
- Humid and wet areas, outdoor installation
DIN VDE 0101 - Set-up of power installations with rated voltages above 1 kV
DIN VDE 0105 - Operation of power installations
DIN VDE 0107 - Electrical installations in hospitals and locations for medical use   outside hospitals
DIN VDE 0108 part 1 - 100 - Power installations and safety power supply in communal facilities,   stores and shops and exhibition rooms, multi-story buildings,   Restaurants, closed car parks and working or business premises
DIN VDE 0113 - Electrical equipment of industrial machines
DIN VDE 0118 - Installation of electrical installations in mines
DIN VDE 0165 - Installation of electrical apparatus in hazardous areas
DIN VDE 0166 - Electrical installations and apparatus thereof for use in   atmospheres potentially endangered by explosive material
DIN VDE 0168 - Electrical installation in open cast mines quarries & similar plants
DIN VDE 0170/0171 - Electrical apparatus for potentially explosive atmospheres
DIN VDE 0185 - Lightning protection system, protection of structures against   lightning
DIN VDE 0207 part 1 - 24 - Insulating and shielding compounds for cables and flexible cords
DIN VDE 0245 part 1 - Cables and cords for electrical and electronic equipment in power   installations
DIN VDE 0245 part 101 - 202 - Flexible PVC-insulated control cable
DIN VDE 0250 part 1 - 819 - Cables, wires and flexible cords for power installation
DIN VDE 0253 - Heating cables
 
Power Guides
DIN VDE 0262 - XLPE (cross linked PE) insulated and PVC shielded installation   cables up to 0.6/1 kV
DIN VDE 0265 - Cables with plastic-insulated lead-jacket for power installation
DIN VDE 0266 part 3 & 4 - Halogen-free cables with improved characteristics in case of fire,   with reduced fire propagation and continuance of isolation for use   in the containment of nuclear power plants
DIN VDE 0267 - Halogen-free cables with improved characteristics in case of fire,   nominal voltages up to 6 to 30 kV
DIN VDE 0271 - PVC-insulated cables and shielded power cables for rated   voltages up to and including 3,6/6 (7,2) kV
DIN VDE 0276 part 603 - Distribution cables of nominal voltages U0 /U 0,6/1 kV
DIN VDE 0276 part 604 - Power cables of nominal voltages U0 /U 0,6/1 kV with special fire   performance for use in power stations
DIN VDE 0276 part 604/605 - Additional test methods
DIN VDE 0276 part 620 - Distribution cables of nominal voltages U0 /U 3,6 kV to 20,8/36 kV
DIN VDE 0276 part 1000 - Current-carrying capacity, general; conversion factors
DIN VDE 0276 part 1001 - Tests on cables laid with nominal voltages U0 /U 6/10 kV, 12/20   kV and 18/30 kV with PVC-insulation, VPE-insulation or paper   insulation
DIN VDE 0277 - Primary cables for airport lighting
DIN VDE 0281 part 1 - 404 - PVC-cables, wires and flexible cords for power installation
DIN VDE 0282 part 1 - 808 - Rubber cables and flexible cords for power installation,
   heat-resistant silicone rubber insulated cable, halogen-free   insulated cable arc welding cable, rubber insulated lift cable,   rubber-shielded flexible cables
DIN VDE 0284 - Mineral insulated cables with a rated voltages not exceeding 750 V
DIN VDE 0289 part 1 - 101 - Definitions for cables, wires & flexible cords for power installation
DIN VDE 0292 - Code designation for harmonized cables and flexible cords for   power installations
DIN VDE 0293 - Conductor identification for cables and flexible cords used in power   installation
DIN VDE 0295 - Conductors of cables, wires and flexible cords for power installation
DIN VDE 0298 part 1 - 300 - Application of cables and flexible cords in power installations
 
Testing, Measurement
DIN VDE 0472 part 1 - 818 - Testing of cables, wires and flexible cords
DIN VDE 0473 up to part 811 - Insulating and shielding materials of electric cables; Common test   methods
DIN VDE 0482 up to part 268 - Measurement of smoke density of cables
 
Telecommunications, Switchboard & Installation Cables
DIN VDE 0800 part 1 - 10 - Telecommunications
DIN VDE 0811 - Ribbon cables with round conductors, with a pitch of 1.27 mm
DIN VDE 0812 - Equipment wires and stranded equipment wires of
  telecommunications system
DIN VDE 0813 - Switchboard cables for telecommunications system
DIN VDE 0814 - Cords for telecommunications system
DIN VDE 0815 - Wiring cables for telecommunications system (indoor cable)
DIN VDE 0816 part 1 - 3 - Outdoor cables for telecommunications system
DIN VDE 0817 - Cables with stranded conductors for increased mechanical stress
  for telecommunications system
DIN VDE 0818 - Self-supporting telecommunication aerial cables on overhead
   power lines above 1 kV
DIN VDE 0839 - Electromagnetic compatibility
DIN VDE 0881 - Equipment wires and flexible equipment wires with extended
  temperature ranges
DIN VDE 0891 part 1 - 10 - Special directions and guiding principles of cables & insulated wires
DIN VDE 0899 part 1 - 5 - Special specification for optical fiber, single conductors, indoor and
  outdoor cables

Sealcon offers over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit Fittings System and Other Related Cable Management Products which are rated the best in the industry.
Liquid Tight Strain Relief, Cord Grips, Cable Gland Fittings Liquid Tight Strain Relief, Cord Grips, Cable Gland Fittings: NPT, Metric, & PG Threads, Materials: Nylon, Nickel Plated Brass, PVDF (for chemicals and extreme temperatures) & Stainless Steel, NEMA 4x and 6 (IP68).
Circular Connectors Circular Connectors (M16, M23, RJ45, M27 and M40): Signal (3-28 pin/socket configurations) & Power (6 & 8 pin/socket configurations). Push-Pull, Stainless Steel, Over Molded Cordsets & Industrial Ethernet.
Conduit System Conduit System: Push-In and Turn-To-Seal Fittings: Straight and 90° Snap Elbow, Double-Seal Fittings, Snapclic DUO: Nylon & Nickel Plated Brass, Bulkhead/Flange, Flexible Corrugated Conduit.
Hazardous Location / Explosive Proof Cord Grips, Cable Glands Hazardous Location / Explosive Proof Cord Grips, Cable Glands: are stamped with the approvals on the products showing your application is EEx e or ATEX compliant.
Materials: Nylon, Nickel Plated Brass, PVDF & Stainless Steel.
Adapters, Enlargers, Reducers Adapters, Enlargers, Reducers: Our Newest product line of Thread Adapters, Thread Reducers, Thread Enlargers! Available in Black or Gray Nylon, Nickel Plated Brass & Stainless Steel.
Cable Accessories Cable Accessories: Locking Nuts, O-Rings, Seal Rings, Dome Plugs, Hex Plugs, Hole Plugs, Socket & Ratchet Wrenches, Multi-Hole & Romex® Inserts.
Hummel Enclosures Hummel Enclosures: Made of Polycarbonate, ABS (Acryl-Butadiene-Styrene), Polystyrene, Aluminum, Steel/Stainless Steel, with Gray or Transparent Lids, available with Hinges and Latches, Plain Walls or Knockouts.

|Cables: Domestic & International|Enclosures (Plastic & Metal)|Liquid Tight Strain Relief Fittings & Accessories|
|Circular Connectors|Conduit System|Camozzi Pneumatics|Cable Index|Enclosure Index|
|Search|Media|Site Map|Company Overview|Contact|Privacy Policy|
14853 E. Hinsdale Ave., Suite D
Centennial, CO 80112-4240 USA
Toll Free: 800-677-8942 / 303-680-5159  Fax: 303-680-5344
To Top of Page Top of Page
Valid XHTML 1.0 Transitional
HomeContactSearch