Your One-Stop Solution For Cable & Wire Accessories!

RoHS Compliant Cables & Wires
Power Cables up to 30 kV, XLPE-Insulated


Contact Us About Us  
 
LinkedIn Facebook Twitter Hi Tech Controls Blog google +
Cables & WiresEnclosures (Plastic & Metal)Pneumatic ComponentsLiquid Tight Strain Relief FittingsCircular ConnectorsConduit System (Tubing, Fittings, etc.)Accessories & Adapters, Reducers, Enlargers
 
easyquote
*E-mail
*Name
*Company
*Phone
*State
*Zip Code
*Country
Please answer the security question:
3+2=
(*) Required Fields
Catalogs / Samples, Full Quote & Contact Information
303-699-1135
1-800-456-9012
dropdownbox
PDF Printable PDF

Power Cables up to 30 KV , XLPE- Insulated

XLPE Insulated, Aluminum Conductor, Single Conductor, Longitudinally Water-Tight, Shielded, PVC Jacket

Sealcon, Inc, European & Domestic cable

NA2XS2Y 6/10 kV, 12/20 kV, 18/30 kV, XLPE insulated, Aluminum conductor, single conductor, shielded, PVC jacket, RoHS compliant, Medium Voltage Power Cables, Power Cablesup to 30 kV, Sealcon, European
Nominal Voltage
6/10 kV
6/10 kV
12/20 kV
12/20 kV
18/30 kV
18/30 kV
European Part-No. Description & No. Conductors x cross-sec. mm2, Nominal Voltage Operation Voltage max. Insul. Thick-ness mm Jacket Thick-ness mm Outer
Dia. min.-max.
Copper Weight
kg/km
Alu Weight kg/km Weight ca. kg/km AWG
32520 NA2XS2Y 6/10kV 1X50 rm/16
12 3.4 2.5 24.0 - 29.0 182.0 145.0 710.0 1
32521 NA2XS2Y 6/10kV 1X70 rm/16 12 3.4 2.5 26.0 - 31.0 182.0 203.0 790.0 2/0
32522 NA2XS2Y 6/10kV 1X95 rm/16 12 3.4 2.5 26.0 - 32.0 182.0 276.0 920.0 3/0
32523 NA2XS2Y 6/10kV 1X120 rm/16 12 3.4 2.5 28.0 - 34.0 182.0 348.0 990.0 4/0
32524 NA2XS2Y 6/10kV 1X150 rm/16 12 3.4 2.5 29.0 - 35.0 182.0 435.0 1110.0 300 kcmil
32525 NA2XS2Y 6/10kV 1X150 rm/25 12 3.4 2.5 29.0 - 35.0 283.0 435.0 1220.0 300 kcmil
32526 NA2XS2Y 6/10kV 1X185 rm/16 12 3.4 2.5 31.0 - 37.0 182.0 537.0 1260.0 350 kcmil
32527 NA2XS2Y 6/10kV 1X185 rm/25 12 3.4 2.5 33.0 - 39.0 283.0 537.0 1370.0 350 kcmil
32528 NA2XS2Y 6/10kV 1X240 rm/16 12 3.4 2.5 33.0 - 39.0 182.0 696.0 1480.0 500 kcmil
32529 NA2XS2Y 6/10kV 1X240 rm/25 12 3.4 2.5 33.0 - 39.0 283.0 696.0 1530.0 500 kcmil
32530 NA2XS2Y 6/10kV 1X300 rm/25 12 3.4 2.5 36.0 - 41.0 283.0 870.0 1820.0 600 kcmil
32531 NA2XS2Y 6/10kV 1X400 rm/35 12 3.4 2.5 40.0 - 45.0 394.0 1160.0 2220.0 750 kcmil
32532 NA2XS2Y 6/10kV 1X500 rm/35 12 3.4 2.5 43.0 - 48.0 394.0 1450.0 2570.0 1000 kcmil

32533 NA2XS2Y 12/20kV 1X50 rm/16
24 5.5 2.5 28.0 - 33.0 182.0 145.0 890.0 1
32534 NA2XS2Y 12/20kV 1X70 rm/16 24 5.5 2.5 30.0 - 35.0 182.0 203.0 970.0 2/0
32535 NA2XS2Y 12/20kV 1X95 rm/16 24 5.5 2.5 31.0 - 36.0 182.0 276.0 1120.0 3/0
32536 NA2XS2Y 12/20kV 1X120 rm/16 24 5.5 2.5 32.0 - 38.0 182.0 348.0 1210.0 4/0
32538 NA2XS2Y 12/20kV 1X150 rm/25 24 5.5 2.5 33.0 - 39.0 283.0 435.0 1420.0 300 kcmil
32537 NA2XS2Y 12/20kV 1X150 rm/16 24 5.5 2.5 33.0 - 39.0 182.0 435.0 1370.0 300 kcmil
32539 NA2XS2Y 12/20kV 1X185 rm/16 24 5.5 2.5 35.0 - 41.0 182.0 537.0 1530.0 350 kcmil
32540 NA2XS2Y 12/20kV 1X185 rm/25 24 5.5 2.5 35.0 - 41.0 283.0 537.0 1570.0 350 kcmil
32542 NA2XS2Y 12/20kV 1X240 rm/25 24 5.5 2.5 38.0 - 44.0 283.0 696.0 1830.0 500 kcmil
32541 NA2XS2Y 12/20kV 1X240 rm/16 24 5.5 2.5 38.0 - 44.0 182.0 696.0 1720.0 500 kcmil
32543 NA2XS2Y 12/20kV 1X300 rm/25 24 5.5 2.5 40.0 - 46.0 283.0 870.0 2070.0 600 kcmil
32544 NA2XS2Y 12/20kV 1X400 rm/35 24 5.5 2.5 43.0 - 49.0 394.0 1160.0 2460.0 750 kcmil
32545 NA2XS2Y 12/20kV 1X500 rm/35 24 5.5 2.5 46.0 - 52.0 394.0 1450.0 2890.0 1000 kcmil

Part-No. Description & No. Conductors x cross-sec. mm2, Nominal Voltage Operation Voltage max. Insul. Thick-ness mm Jacket Thick-ness mm Outer
Dia. min.-max.
Copper Weight
kg/km
Alu Weight kg/km Weight ca. kg/km AWG
32546 NA2XS2Y 18/30kV 1X50 rm/16
36 8.0 2.5 32.0 - 38.0 182.0 145.0 1120.0 1
32547 NA2XS2Y 18/30kV 1X70 rm/16 36 8.0 2.5 34.0 - 40.0 182.0 203.0 1270.0 2/0
32548 NA2XS2Y 18/30kV 1X95 rm/16 36 8.0 2.5 35.0 - 41.0 182.0 276.0 1380.0 3/0
32549 NA2XS2Y 18/30kV 1X120 rm/16 36 8.0 2.5 37.0 - 43.0 182.0 348.0 1530.0 4/0
32550 NA2XS2Y 18/30kV 1X150 rm/25 36 8.0 2.5 38.0 - 44.0 283.0 435.0 1720.0 300 kcmil
32551 NA2XS2Y 18/30kV 1X150 rm/25 36 8.0 2.5 40.0 - 46.0 283.0 537.0 1860.0 350 kcmil
32552 NA2XS2Y 18/30kV 1X240 rm/25 36 8.0 2.5 42.0 - 48.0 283.0 696.0 2110.0 500 kcmil
32553 NA2XS2Y 18/30kV 1X300 rm/25 36 8.0 2.5 45.0 - 51.0 283.0 870.0 2370.0 600 kcmil
32554 NA2XS2Y 18/30kV 1X400 rm/35 36 8.0 2.5 48.0 - 54.0 394.0 1160.0 2820.0 750 kcmil
32555 NA2XS2Y 18/30kV 1X500 rm/35 36 8.0 2.5 51.0 - 57.0 394.0 1450.0 3280.0 1000 kcmil
Technical Data European
  • XLPE-insulated power cables to DIN VDE 0276 part 620, HD 620 S1 and IEC 60502
  • Temperature Range
    During installation up to -20°C/-4°F
  • Operating Temperature
    Max. +90°C/194°F
  • Short Circuit Temperature
    +250°C/482°F (short circuit duration up to 5 sec.)
  • Nominal Voltages
    U0/U 6/10 kV, 12/20 kV, 18/30 kV
  • Operating Voltages for
    6/10 kV = max. 12 kV
    12/20 kV = max. 24 kV
    18/30 kV = max. 36 kV
  • Test Voltages for
    6/10 kV = 15 kV
    12/20 kV = 30 kV
    18/30 kV = 45 kV
  • MinimumBending Radius
    During installation max. 15x cable Ø
  • Power Ratings Table
    See Technical Information
Code-Designation for Power Cables with PVC or XLPE Insulation
Design Identification of Design Explanations
Conductor N According to VDE Standard
(No abbreviation for copper conductor)
A Aluminum conductors
Y Insulation of thermoplastic Polyvinyl chloride (PVC)
2X Insulation cross-linked Polyethylene (XLPE)
Concentric Conductor, Shielding C Concentric conductors of copper wires and copper tape, helically wounded
CW Concentric conductors of copper wires in wave conal formation and and copper tape, helically wounded
CE Concentric conductors of copper wires and copper tape over each individual conductor, helically wounded
Shielding S Shielding of copper wires and copper tape, helically wounded
SE Shielding of copper wires and copper tape over each individual conductor, helically wounded
(F) Longitudinally water-proof shielding
Armor B Armor of steel tape
F Armor of galvanized flat steel wires
G Counter helix of galvanized steel tape
Jacket K Lead jacket
Outer Jacket Y PVC jacket
2Y PE jacket
Cable for U0/U 0.6/1 kV are additionally designated with
  -J Cables with green-yellow (green-natural) conductor are marked with protective conductor
-O Cables without green-yellow (green-natural) conductor are marked without protective conductor
Approvals
RoHS VDE
Cable Construction  
  • Circular bare aluminum-conductor of stranded wires to HD 383
  • Inner semi-conducting coating
  • Conductor insulation of cross-linked Polyethylene (XLPE), PE-compound DIX8 to HD 620.1
  • Outer extrusion of semi-conducting coating spliced with the insulation
  • Wrapping of conductive material
  • Shield: Braiding of copper wires with one or two tapes applied helically
  • Wrapping
  • PE-outer jacket black, compound DMP2 to HD 620.1
  • Jacket color: Black
Application  
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switch-boards and power stations. The PE-outer jacket is resistant to high mechanical stress for laying the cables. This PE-jacket is not flame-resistant (does not conform the test method B, as per VDE 0472 part 804).
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures a construction free of partial discharges with high operational reliability.
Properties  
  • The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
  • Installation Notes
    To guarantee an optimum on operating reliability the extruded semi-conductive layer is spliced with the insulation for long duration. For this reason, we recommend a peeling tool for installation.
Note  
  • Further dimensions available on request.
Cable Accessories  
  • Coming Soon!
Cable Technical Data Construction and ApplicationProperties and Note Accessories
quote
Items For Quote

   
quote
box
 
Sealcon is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135 FAX: 303-680-5344
Valid XHTML 1.0 Transitional
To Top of Page Top of Page

Copyright © Sealcon All Rights Reserved
|Domestic & International Cables|Enclosures |Liquid Tight Strain Relief Fittings & Accessories|
|Circular Connectors|Conduit System|Pneumatics|Cable Index|Enclosure Index|Search|
|Media|Site Map|Company Overview|Contact|Privacy Policy|Copyright Notice|