Your One-Stop Solution For Cable & Wire Accessories!

RoHS Compliant Cables & Wires
Internationally Approved Cables


Contact Us Site Map  
 
Follow us:  LinkedIn Facebook Twitter Hi Tech Controls Blog
Cables & WiresEnclosures (Plastic & Metal)Pneumatic ComponentsLiquid Tight Strain Relief FittingsCircular ConnectorsConduit System (Tubing, Fittings, etc.)Accessories & Adapters, Reducers, Enlargers
 
easyquote
*E-mail
*Name
*Company
*Phone
*State
*Zip Code
*Country
(*) Required Fields
Catalogs / Samples, Full Quote & Contact Information
Quote Request 1-800-677-8942
Catalog & Samples
Contact Information, Phone
dropdownbox
dropdownbox

THE EXCLUSIVE IMPORTER OF Helukabel Cables & Wires
WE PROVIDE CUSTOMERS WITH CABLE MANAGEMENT SOLUTIONS!
-Quantity Discounts! -No Minimum Orders! -Inventory in Excess of $25 Million!
-Blanket Orders! -Quick and Friendly Service! -All Major Credit Cards!
PDF Printable PDF

Helukabel Internationally Approved Cable: JZ 604 TC TRAY CABLE

PVC Power Cable, Exposed Run, +90°C/+194°F, 600V, Meter Marking

Hi-Tech Controls, Inc, HELUKABEL wires and cables

JZ 604 TC TRAY CABLE PVC power cable, 90°C, 600V, RoHS Approved, RoHS Compliant, Helukabel, Hi-Tech Controls
AWG Selection
17
17
16
16
14
14
12
12
10
10
8
8
6
6
4 4 2 2 1 1 2/0 2/0 3/0 3/0 4/0 4/0    
Helukabel Part-No. Description & No. Conductors x cross-sec. mm2

Outer
Diameter
mm

Copper Weight
kg/km
Weight
ca. kg/km
AWG
69661 JZ-604 TC 2X1 TRAY CABLE 8.0 19.2 74.0 17
69662 JZ-604 TC 3G1 TRAY CABLE 8.4 29.0 87.0 17
69663 JZ-604 TC 4G1 TRAY CABLE 9.1 39.0 99.0 17
69664 JZ-604 TC 5G1 TRAY CABLE 10.0 48.0 117.0 17
69665 JZ-604 TC 7G1 TRAY CABLE 11.7 67.0 151.0 17
69666 JZ-604 TC 9G1 TRAY CABLE 12.6 84.0 172.0 17
69667 JZ-604 TC 10G1 TRAY CABLE 14.3 96.0 206.0 17
69668 JZ-604 TC 12G1 TRAY CABLE 14.7 115.0 260.0 17
69669 JZ-604 TC 18G1 TRAY CABLE 17.1 173.0 371.0 17
69670 JZ-604 TC 25G1 TRAY CABLE 20.3 240.0 481.0 17
69671 JZ-604 TC 34G1 TRAY CABLE 23.7 326.0 551.0 17
69672 JZ-604 TC 50G1 TRAY CABLE 26.1 480.0 959.0 17
69673 JZ-604 TC 2X1.5 TRAY CABLE 8.4 28.8 91.0 16
69674 JZ-604 TC 3G1.5 TRAY CABLE 8.8 43.0 105.0 16
69675 JZ-604 TC 4G1.5 TRAY CABLE 9.6 58.0 122.0 16
69676 JZ-604 TC 5G1.5 TRAY CABLE 10.5 72.0 147.0 16
69677 JZ-604 TC 7G1.5 TRAY CABLE 12.3 101.0 192.0 16
69678 JZ-604 TC 8G1.5 TRAY CABLE 13.3 115.0 213.0 16
69679 JZ-604 TC 9G1.5 TRAY CABLE 13.3 130.0 261.0 16
69680 JZ-604 TC 10G1.5 TRAY CABLE 15.1 144.0 294.0 16
69681 JZ-604 TC 12G1.5 TRAY CABLE 15.6 173.0 331.0 16
69682 JZ-604 TC 16G1.5 TRAY CABLE 17.1 230.0 402.0 16
69683 JZ-604 TC 18G1.5 TRAY CABLE 18.2 259.0 430.0 16
69684 JZ-604 TC 25G1.5 TRAY CABLE 22.7 360.0 597.0 16
69685 JZ-604 TC 34G1.5 TRAY CABLE 25.3 489.0 714.0 16
69686 JZ-604 TC 41G1.5 TRAY CABLE 26.7 590.0 803.0 16
69687 JZ-604 TC 50G1.5 TRAY CABLE 27.3 720.0 1021.0 16
69688 JZ-604 TC 61G1.5 TRAY CABLE 29.4 878.0 1238.0 16
69689 JZ-604 TC 2X2.5 TRAY CABLE 9.4 48.0 111.0 14
69690 JZ-604 TC 3G2.5 TRAY CABLE 9.9 72.0 140.0 14
69691 JZ-604 TC 4G2.5 TRAY CABLE 10.8 96.0 161.0 14
69692 JZ-604 TC 5G2.5 TRAY CABLE 11.8 120.0 194.0 14
69693 JZ-604 TC 7G2.5 TRAY CABLE 14.7 168.0 257.0 14
69694 JZ-604 TC 8G2.5 TRAY CABLE 16.0 192.0 339.0 14
69695 JZ-604 TC 9G2.5 TRAY CABLE 16.0 216.0 341.0 14
69696 JZ-604 TC 10G2.5 TRAY CABLE 17.1 240.0 392.0 14
69697 JZ-604 TC 12G2.5 TRAY CABLE 17.7 288.0 470.0 14
69698 JZ-604 TC 18G2.5 TRAY CABLE 20.8 432.0 682.0 14
69699 JZ-604 TC 25G2.5 TRAY CABLE 25.8 600.0 891.0 14
Helukabel Part-No. Description & No. Conductors x cross-sec. mm2 Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
69700 JZ-604 TC 3G4 TRAY CABLE 11.0 115.0 190.0 12
69701 JZ-604 TC 4G4 TRAY CABLE 12.0 154.0 229.0 12
69702 JZ-604 TC 5G4 TRAY CABLE 13.2 192.0 284.0 12
69703 JZ-604 TC 7G4 TRAY CABLE 16.5 269.0 394.0 12
69704 JZ-604 TC 9G4 TRAY CABLE 17.8 346.0 480.0 12
69705 JZ-604 TC 12G4 TRAY CABLE 19.9 461.0 841.0 12
69706 JZ-604 TC 18G4 TRAY CABLE 24.2 691.0 981.0 12
69707 JZ-604 TC 3G6 TRAY CABLE 12.5 173.0 290.0 10
69708 JZ-604 TC 4G6 TRAY CABLE 14.5 230.0 384.0 10
69709 JZ-604 TC 5G6 TRAY CABLE 15.8 288.0 468.0 10
69710 JZ-604 TC 7G6 TRAY CABLE 17.3 403.0 654.0 10
69711 JZ-604 TC 3G10 TRAY CABLE 16.9 288.0 511.0 8
69712 JZ-604 TC 4G10 TRAY CABLE 18.6 384.0 587.0 8
69713 JZ-604 TC 5G10 TRAY CABLE 20.4 480.0 784.0 8
69714 JZ-604 TC 7G10 TRAY CABLE 23.5 672.0 970.0 8
69715 JZ-604 TC 3G16 TRAY CABLE 21.0 461.0 651.0 6
69716 JZ-604 TC 4G16 TRAY CABLE 23.9 614.0 869.0 6
69717 JZ-604 TC 5G16 TRAY CABLE 26.3 768.0 1117.0 6
69718 JZ-604 TC 7G16 TRAY CABLE 28.8 1075.0 1364.0 6
69719 JZ-604 TC 3G25 TRAY CABLE 24.9 720.0 1090.0 4
69720 JZ-604 TC 4G25 TRAY CABLE 27.2 960.0 1421.0 4
69721 JZ-604 TC 5G25 TRAY CABLE 30.3 1200.0 1611.0 4
69722 JZ-604 TC 7G25 TRAY CABLE 33.1 1680.0 1943.0 4
69723 JZ-604 TC 3G35 TRAY CABLE 27.1 1008.0 1734.0 2
69724 JZ-604 TC 4G35 TRAY CABLE 29.8 1344.0 2011.0 2
69725 JZ-604 TC 5G35 TRAY CABLE 33.0 1680.0 2347.0 2
69726 JZ-604 TC 3G50 TRAY CABLE 33.2 1440.0 2041.0 1
69727 JZ-604 TC 4G50 TRAY CABLE 36.7 1920.0 2539.0 1
69728 JZ-604 TC 5G50 TRAY CABLE 41.5 2400.0 2894.0 1
69729 JZ-604 TC 3G70 TRAY CABLE 37.6 2016.0 2831.0 2/0
69730 JZ-604 TC 4G70 TRAY CABLE 42.0 2688.0 3494.0 2/0
69731 JZ-604 TC 5G70 TRAY CABLE 47.6 3360.0 4260.0 2/0
69732 JZ-604 TC 3G95 TRAY CABLE 41.8 2736.0 5010.0 3/0
69733 JZ-604 TC 4G95 TRAY CABLE 47.0 3648.0 6104.0 3/0
69734 JZ-604 TC 5G95 TRAY CABLE 52.5 4560.0 7891.0 3/0
69735 JZ-604 TC 3G120 TRAY CABLE 46.0 3456.0 5940.0 4/0
69736 JZ-604 TC 4G120 TRAY CABLE 51.5 4608.0 7604.0 4/0
69737 JZ-604 TC 5G120 TRAY CABLE 56.5 5760.0 8751.0 4/0
Technical Data Helukabel
  • PVC power cable to UL-standard 1277
    TRAY CABLE
  • Multi Norm
    The TRAY CABLE also conforms to the following standards:
    AWM-Style 2587 to UL-Std. 758
    CSA C22.2 No 210.2 I/II A/B 90C 600 V
  • Temperature Range
    Dry Environment
    Flexing
    -5°C to +90°C (+23°F to +194°F)
    Fixed Installation
    -25°C to +90°C (-13°F to +194°F)
    Wet Environment
    Flexing
    -5°C to +75°C (+23°F to +167°F)
    Fixed Installation
    -25°C to +75°C (-13°F to +167°F)
  • Nominal Voltage to UL 600 V
  • Test Voltage 3000 V
  • Breakdown Voltage min. 6000 V
  • Insulation Resistance
    Min. 20 MOhm x km
  • Minimum Bending Radius
    7.5x cable Ø
  • Radiation Resistance
    Up to 80x106 cJ/kg (up to 80 Mrad)
Approvals
RoHSUL CSA AWM
Cable Construction  
  • Bare copper, fine wire conductors, according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5
  • Special PVC conductor insulation class 12 B to table 50.155 UL-standard 1581,
    type TFF to UL-Std. 62 table 6.2 (AWG 20-AWG 16),
    type THHW to UL-Std. 83 table 5.2 (AWG 14)
  • Black conductors with continuous white numbering according to DIN VDE 0293
  • Green-yellow earth conductor in the outer layer (3 conductors and above)
  • Conductors stranded in layers with optimal lay-length
  • Special PVC outer jacket, to UL-Std. 1277 table 11.2
  • Jacket color: Black (RAL 9005)
Application  

USA NFPA79, edition 2007 conformant flexible power cables up to 600 V, for all machinery in tool and plant construction, suitable for installation in dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation from the cable rack to machines and industrial plants.
CE Approval = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.

Properties  
  • Material self-extinguishing and flame retardant to UL-Standard 1277
  • The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Note  
  • G = with green-yellow earth conductor;
    x = without green-yellow earth conductor (OZ).
  • AWG sizes are approximate equivalent values. The actual cross-section is in mm².
Cable Accessories  
  • Coming Soon!
Cable Technical Data Construction and ApplicationProperties and Note Accessories
quote
Items For Quote

   
quote
box
Internationally Approved Cables
C.N.O.M.O.
Command Cable UL (LiYCY) 300V
Command Cable UL (LiYCY) 600V
Command Cable UL (LiYCY-TP)
Command Cable UL (LiYY) 300V
Command Cable UL (LiYY) 600V
Command Cable UL (LiYY-TP)
FIVENORM
FROR CEI 20-22 II
H05VV-F/SJT: Black & Gray
H05VV-SJT: Orange
H05VV-F/UL
H07RN-F/SOOW
Helukabel BS 5308 Part 1
Helukabel BS 5308 Part 2
Helukabel BS 5467
Helukabel BS 6724
HELUTHERM 145: 300 V
HELUTHERM 145: 600 V
HELUWIND WK 103k EMI D-T, WK 103k-T
HELUWIND WK 103w EMI D-T, WK 103w-T
HELUWIND 105, WK105 D-EMI
HELUWIND WK115 D-EMI Torsion, WK 115-Torsion
JZ-600 PUR
JZ-600 UL/CSA
JZ-600-YC-PUR UL/CSA
JZ-600-Y-CY UL/CSA
JZ-602
JZ-602-CY UL/CSA
JZ-602-PUR
JZ-602-C-PUR
JZ-602-PUR DC/AC
JZ-602 RC
JZ-602 RC-PUR
JZ-602 RC-C-PUR
JZ-602 RC-CY
JZ-603
JZ-603-CY
JZ-604-FCY TC TRAY CABLE
JZ-604-YCY TC TRAY CABLE
JZ-604 TC TRAY CABLE
MEGAFLEX 500
MEGAFLEX 500-C
MOTORFLEX EMV 1/1
MOTORFLEX-X EMV 1/1
MOTORFLEX-EMV 3/3
MULTIFLEX® 512-PUR UL/CSA
MULTIFLEX® 512-C-PUR UL/CSA
MULTIFLEX 600
MULTIFLEX 600-C
MULTISPEED® 500-PUR UL/CSA
MULTISPEED® 500-C-PUR UL/CSA
MULTISPEED® 500-PVC UL/CSA
MULTISPEED® 500-C-PVC UL/CSA
MULTISPEED® 500-TPE UL/CSA
MULTISPEED® 500-C-TPE UL/CSA
MULTISPEED 600-PUR -J/-O
MULTISPEED 600-C-PUR -J/-O
MULTISPEED® TRONIC-PUR
MULTISPEED® TRONIC-C-PUR
OB-602 PUR YELLOW
PVC Single Conductor
ROBOFLEX Recycle
Rubber / Neoprene Control Cable
SiHF UL/CSA
SiHF-C-Si UL/CSA
SINGLE 600 -J/-O
SINGLE 600-CY -J/-O
SINGLE 602-RC -J/-O
SINGLE 602-RC-CY -J/-O
SUPER-PAAR-TRONIC-340-C-PUR
SUPERTRONIC-310-PVC
SUPERTRONIC-310-C-PVC
SUPERTRONIC-330 PURÖ
SUPERTRONIC-C-PURÖ
THHN / THWN
THREENORM
TOPFLEX® 301/301-UL
TOPFLEX® 302/302-UL
TOPFLEX® 304/304-C
TOPFLEX® 1002
TOPFLEX®-MOTOR-EMV 103
TOPFLEX® 600 VFD
TOPFLEX® 650 VFD
TOPGEBER 510
TOPGEBER 512
TOPSERV® 600 VFD
TOPSERV® 650 VFD
TOPSERV® 109
TOPSERV® 113/127
TOPSERV® 121
TOPSERV® 150
TRAYCONTROL 300
TRAYCONTROL 300-C
TRAYCONTROL 300 TP
TRAYCONTROL 300-C TP
TRAYCONTROL 500
TRAYCONTROL 500-C
TRAYCONTROL 600
TRAYCONTROL 600-C
TROMM-PUR-H
UL-Style 1007, CSA TR 64
UL-Style 1015
UL-Style 1569, CSA TR 64
UL-Style 3135
VERTEILERFLEX, 2 Approvals
box

Sealcon is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
Liquid Tight Strain Relief, Cord Grips, Cable Gland FittingsLiquid Tight Strain Relief Fittings, Cord Grips, Cable Glands
Threads: PG, NPT, Metric, BSPP Threads
Materials: Nylon, Nickel Plated Brass, PVDF (for chemicals and extreme temperatures) & Stainless Steel, NEMA 4x and 6 (IP68, IP 69K).
Approvals: RoHS, Deca BDE, UR, UL, CE, CSA, VDE, German Lloyd, etc.
UL f1 (UL 746C) - Suitable for outdoor use with respect to exposure to ultraviolet light, water exposure and immersion in accordance with UL 746C
Circular ConnectorsCircular Connectors (M16, M23, RJ45, M27 and M40)
Sizes: M16 Signal, M23 Signal & Power, M27 Signal, M40 Power, M12/16 Twintus
Types: Twintus, RJ45 Industrial Ethernet, PoE Fast Ethernet, Push-Pull, Stainless Steel, Over Molded Cordsets, Standard/EMI Ready
Configurations: Signal (3-28 pole) & Power (6 & 8 pole)
Materials: Nickel Plated Brass, Stainless Steel and Aluminum
Approvals: RoHS, Deca BDE, UR, UL, CSA, TÜV, etc.
Hummel EnclosuresIndustrial Enclosures (Plastic & Metal)
Materials: Polycarbonate, ABS (Acryl-Butadiene-Styrene), Aluminum, Steel/Stainless Steel and Polyester.
Types: Gray or Transparent Lids, available with Hinges and Latches, Plain Walls or Knockouts.
Approvals: RoHS, Deca BDE, UL, CSA, TUV and CE. Modular, Expandable, UV and Impact Resistant, NEMA 4, 4x (IP 66/67). Solar Plus for Photovoltaic applications.
Our Enclosures can be equipped with Strain Relief Fittings, Circular Connectors or Conduit Fittings. Other customization options like cutting & drilling are also available.
Conduit SystemConduit System
High Pull-Out Resistance, Robust Performance, Long Life Expectancy, Fastest/ Easy installation, No Tools required!
Fittings:
Push-In, Turn-to-Seal, Snapclic DUO (Nylon or Nickel Plated Brass), Double-Seal, Flange/Bulkhead
Conduit:
Standard and Super Flex Corrugated Conduit
Accessories: Snap-In Mounting Brackets. NEMA 4 (IP 54/65)
Approvals: RoHS, Deca BDE, UR, German Lloyd, CE, etc.
Hazardous Location / Explosive Proof Cord Grips, Cable GlandsHazardous Location / Explosive Proof Cord Grips, Cable Glands
These fittings are labeled and approved to withstand the required needs of a combustible environment.
Materials: Nylon, Nickel Plated Brass, PVDF (chemical resistant & extreme temperatures), Stainless Steel.
Threads: NPT, Metric & PG. NEMA 4x (IP 67) and 6 (IP 68/69K)
Approvals:
RoHS, Deca BDE, UL, CSA, VDE, CE, EEx e, ATEX, German Lloyd, IECEx,
Ex-d/Ex-e, Ex-i
EXIOS - High-end Cable Glands for armored cables in hazardous areas including the latest IECEx and ATEX certifications, for use in Ex-e, Ex-d and Ex-tD areas
Adapters, Enlargers, ReducersThread Adapters, Enlargers, Reducers
Convert, Increase or Decrease your thread size with our newest product line of Adapters, Enlargers and Reducers.
Threads: NPT, Metric and PG.
Materials: Black or Gray Nylon, Nickel Plated Brass, Aluminum, Stainless Steel.
Approvals: RoHS, Deca BDE, CE, EEe x, ATEX, etc.
Hazardous / Explosive proof versions available.
Cable AccessoriesCable Accessories
Locking Nuts:Black & Gray Nylon, Nickel Plated Brass, Zinc Plated Steel, EMI (w/ Cutting Edges)
O-Rings: Buna-N, Viton®, Silicone
Seal Rings: Polyethylene / Fiber-reinforced Plastic
Hole Plugs: Dome, Hex, Nylon, Nickel Plated Brass
Inserts: Standard, Reduced, Multi-Hole, Romex®
Other Accessories: Ratchet & Socket Wrenches, Cable Clamps, etc.
14853 E. Hinsdale Ave.
Centennial, CO 80112-4240 USA
Toll Free: 800-677-8942 / 303-680-5159 FAX: 303-680-5344
Valid XHTML 1.0 Transitional
To Top of Page Top of Page

Copyright © 2012 Hi-Tech Controls Inc. All Rights Reserved
|Cables: Domestic & International|Enclosures (Plastic & Metal)|Liquid Tight Strain Relief Fittings & Accessories|
|Circular Connectors|Conduit System|Camozzi Pneumatics|Cable Index|Enclosure Index|Search|
|Media|Site Map|Company Overview|Contact|Privacy Policy|Copyright Notice|